MN-36580 (Rev. 2) 01/16 • Quickchillers • 14
s u b t I t l e
t I t l e
e l e c t r I c a l
I n s t a l l a t I o n
This appliance must be branch circuit protected with
proper ampacities, in accordance with the wiring
diagram. The Quickchiller must be properly grounded
in accordance with the National Electrical Code
and applicable local codes. Wire size for the main
incoming power to the unit must match the minimum
size listed in the specifications applicable to the
specific Quickchiller model. For supply connections,
locate the wire size listed in this manual.
Before operating the chiller, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NotICE
:
after electrical connections have been
completed, operate the appliance in any
chilling mode for a period of 15 minutes
and recheck the main power connections
at the terminal block to make certain
they remain tight.
W a r n I n g
To prevent SERIOUS INJURY,
DEATH, or PROPERTY DAMAGE:
All electrical connections must be
made by a qualified and trained
service technician in accordance
with applicable electrical codes.
This appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence
of local codes, with the current
edition of the National Electrical
Code ANSI/NFPA No. 70. In Canada,
all electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
W a r n I n g
To prevent SERIOUS INJURY, DEATH
or PROPERTY DAMAGE:
All electrical connections must be
made by a qualified and trained
service technician in accordance with
applicable electrical codes.
voltage
phase
cycle
/
hz
QC2-3
QC2-20
QC2-40
QC2-100
QC2-100r
remote
115V
1 ph
60 Hz
recommended
circuit
amperage
:
plug
configuration
:
16A, 1.8kW
20 amps
NEMA 5-20P
16A, 1.8kW
20 amps
NEMA 5-20P
not
available
not
available not
available
115/208-230V 1 ph
60 Hz
recommended
circuit
amperage
:
plug
configuration
:
not
available
not
available
16A, 3.7kW
20 amps
NEMA 14-20P
24A, 5.5kW
30 amps
4 wire direct
20A, 4.6kW
30 amps
4 wire direct
115/208-230V 3 ph
60 Hz
recommended
circuit
amperage
:
recommended
wire
size
:
not
available
not
available
not
available
16A, 3.7kW
20 amps
5 wire direct
not
available
220V
1 ph
50 Hz
recommended
circuit
amperage
:
recommended
wire
size
:
8a, 1.8
k
W
20 amps
NeMa 5-15p
14A, 1.8kW
20 amps
3 wire direct
20A, 4.4kW
30 amps
5 wire direct
20A, 4.4kW
30 amps
3 wire direct
16A, 3.5kW
20 amps
3 wire direct
380-420V
3 ph
50 Hz
recommended
circuit
amperage
:
recommended
wire
size
:
not
available
not
available
10A, 3.8kW
20 amps
5 wire direct
12A, 4.6kW
20 amps
5 wire direct
7A, 2.7kW
15 amps
5 wire direct
electrIcal specIfIcatIons
Wire diagrams are located near the top of the
unit, close to the compressor or control panel.
Electrical Specifications