Rockwell Automation Publication 750-IN001O-EN-P - October 2014
255
I/O Wiring
Chapter 5
22-Series I/O Module
Table 59 - Input Mode Jumpers
Table 60 - TB1 Terminal Designations
20-750-2262C-2R
(24 Volts DC)
20-750-2263C-1R2T
(24 Volts DC)
20-750-2262D-2R
(120 Volts AC)
Jumper
Position
Voltage Mode
Current Mode
Terminal
Name
Description
Related
Param
(5)
(5) I/O Module parameters will also have a Port designation.
Sh
Shield
Terminating point for wire shields when an EMC plate
or conduit box is not installed.
Sh
Ptc–
Motor PTC (–)
Motor protection device (Positive Temperature
Coefficient).
(2)
(2) See HW Input PTC on
for PTC data.
40
on Port X
Ptc+
Motor PTC (+)
Ao0–
Analog Out 0 (–)
Bipolar, ±10V, 11 bit & sign, 2 k ohm minimum load.
4-20 mA, 11 bit & sign, 400 ohm maximum load.
75
on Port X
Ao0+
Analog Out 0 (+)
Ao1–
Analog Out 1 (–)
85
on Port X
Ao1+
Analog Out 1 (+)
–10V
–10 Volt Reference
2k ohm minimum.
10VC
10 Volt Common
For (–) and (+) 10 Volt references.
+10V
+10 Volt Reference
2k ohm minimum.
Ai0–
Analog Input 0 (–)
Isolated
(3)
, bipolar, differential, 11 bit & sign.
Voltage Mode: ±10V @ 88k ohm input impedance.
Current Mode: 0-20 mA @ 93 ohm input impedance.
(3) Differential Isolation - External source must be maintained at less than 160V with respect to PE. Input provides high common mode
immunity.
50, 70
on Port X
Ai0+
Analog Input 0 (+)
Ai1–
Analog Input 1 (–)
60, 70
on Port X
Ai1+
Analog Input 1 (+)
24VC
24 Volt Common
Drive supplied logic input power.
200 mA max. per I/O module
600 mA max per drive
+24V
+24 Volt DC
Di C
Digital Input Common Common for Digital Inputs 0…5
Di 0
Digital Input 0
(1)
(1) Digital Inputs are either 24 Volts DC (2262C) or 115 Volts AC (2262D) based on module catalog number. Ensure applied voltage is
correct for I/O module.
24V DC (30V DC Max.) - Opto isolated
High State: 20…24V DC 11.2 mA DC
Low State: 0…5V DC
120V AC (132V AC Max.) 50/60 Hz
(4)
- Opto isolated
High State: 100…132V AC
Low State: 0…30V AC
(4) For CE compliance use shielded cable. Cable length should not exceed 30 m (98 ft).
1
on Port X
Di 1
Digital Input 1
(1)
Di 2
Digital Input 2
(1)
Di 3
Digital Input 3
(1)
Di 4
Digital Input 4
(1)
Di 5
Digital Input 5
(1)
Ai0
Ai1
Ai0
Ai1
Sh
Sh
PTC–
PTC+
Ao0–
Ao0+
Ao1–
Ao1+
–10V
10VC
+10V
Ai0–
Ai0+
Ai1–
Ai1+
24VC
+24V
DiC
Di0
Di1
Di2
Di3
Di4
Di5
Summary of Contents for PowerFlex 20-750-20COMM
Page 1: ...PowerFlex 750 Series AC Drives Catalog Numbers 20F 20G 21G Installation Instructions...
Page 6: ...6 Rockwell Automation Publication 750 IN001O EN P October 2014 Notes...
Page 10: ...10 Rockwell Automation Publication 750 IN001O EN P October 2014 Preface Notes...
Page 218: ...218 Rockwell Automation Publication 750 IN001O EN P October 2014 Chapter 4 Power Wiring Notes...
Page 301: ......