I/O Wiring
20-COMM Carrier
Enables use of some 20-COMM adapters with PowerFlex 750-Series drives. See
for instructions on installing a 20-
COMM adapter on the 20-COMM Carrier.
Table 84 - 20-COMM-* Network Adapter Compatibility with 750-Series Drives
Frame 1 Drives Installation Recommendations
•
PowerFlex Frame 1 drives require the use of the 20-750-20COMM-F1
Communication Carrier kit. This kit contains the required adapter plate.
•
Only install the 20-750-20COMM-F1 Communication Carrier in Port 4.
See
for port locations. Port 5 will not be accessible when this
module is installed.
Frame 2 and Larger Drives Installation Recommendations
•
Installing the 20-750-20COMM Communication Carrier in Port 6 is
recommended. Installing in Port 4 or Port 5 will make the adjacent left
port inaccessible to other option modules, and may interfere with network
cable connections.
20-750-20COMM-F1
20-750-20COMM
Frame 1
Frames 2 and Larger
Adapter
Accesses Ports 0…6
for I/O Connections
(Implicit and Explicit Messaging)
Accesses Ports 7 and
Higher
(I/O, Explicit
Messaging)
Supports Drive Add-on
Profiles
Supports Asian-
Languages
(6)
(6) Chinese, Japanese, and Korean languages are supported at the time of publication.
Cat. No.
Type
20-COMM-B
BACnet MS/TP
Not Compatible
20-COMM-C
ControlNet
(Coax)
✓
v3.001
(4)
✓
v3.001
(4)
(4) Requires this adapter firmware version or higher.
✓
(5)
(5) Requires firmware version v1.05 or higher of the drive Add-on Profiles for RSLogix 5000 version v16 or higher.
✓
v3.001
(4)
20-COMM-D
DeviceNet
✓
(2)
(2) Controller must be capable of reading/writing 32-bit floating point (REAL) values.
Not Compatible
20-COMM-E
EtherNet/IP
✓
v4.001
(4)
✓
v4.001
(4)
✓
(5)
✓
v4.001
(4)
20-COMM-H
RS-485 HVAC
✓
v2.009
(3) (4)
(3) Supports all three modes of operation (RTU, P1, N2).
Not Compatible
20-COMM-K
CANopen
✓
v1.001
(4)
20-COMM-L
LonWorks
✓
v1.007
(4)
20-COMM-M
Modbus/TCP
✓
v2.001
(4)
✓
v2.001
(4)
Not Compatible
✓
v2.001
(4)
20-COMM-P
ControlNet
(Fiber)
✓
v1.006
(4)
✓
v1.006
(4)
Not Compatible
20-COMM-Q
PROFIBUS DP
✓
v3.001
(4)
✓
v3.001
(4)
✓
(5)
✓
v3.001
(4)
20-COMM-R
(1)
(1) This item has
status.
Remote I/O
✓
(2)
Not Compatible
20-COMM-S
RS-485 DF1
✓
(2)
Summary of Contents for PowerFlex 20-750-20COMM
Page 1: ...PowerFlex 750 Series AC Drives Catalog Numbers 20F 20G 21G Installation Instructions...
Page 6: ...6 Rockwell Automation Publication 750 IN001O EN P October 2014 Notes...
Page 10: ...10 Rockwell Automation Publication 750 IN001O EN P October 2014 Preface Notes...
Page 218: ...218 Rockwell Automation Publication 750 IN001O EN P October 2014 Chapter 4 Power Wiring Notes...
Page 301: ......