116
Rockwell Automation Publication 1756-UM010C-EN-P - June 2021
Appendix B Software Configuration Tags
O.Total[0].StaticGaugePressure
Float
REAL
Pressure in psig of output connected to channel 0
O.Total[0].BasePressure
Float
REAL
Pressure in psig of output connected to channel 0
O.Total[0].BaseCompressibility
Float
REAL
Default = 1
O.Total[0].FlowingCompressibility
Float
REAL
Default = 1
O.Total[0].FillTotalTarget
Float
REAL
Target for Fill Complete, except when Fill Transition is greater than this
value.
O.Total[0].FillTransition
Float
REAL
When fill cycle is started, trickle flow is initiated when the Fill Total is
equal to or greater than this value. Full flow is initiated when the Fill Total
is less than this value.
O.Total[0].FillTransitionTimer
Float
REAL
When timed trickle flow is selected, the status remains ON for this time
during this state.
The value must be changed prior to entering the trickle flow state.
O.Total[1].AlarmEnables
Binary
SINT
O.Total[1].Overrange
Decimal
BOOL
Enables the Overrange alarm on output connected to channel 1. When the
Frequency Period exceeds 100KHz, this alarm is set.
0 = No Alarm
1 = Alarm Enabled
O.Total[1].Overflow
Decimal
BOOL
Enables the Overflow alarm on output connected to channel 1. When the
Total Counts exceeds the Roll Over value, this alarm is set.
0 = No Alarm
1 = Alarm Enabled
O.Total[1].Overspeed
Decimal
BOOL
Enables the Overspeed alarm on output connected to channel 1. When the
Speed exceeds the Highest Allowed Frequency value, this alarm is set.
0 = No Alarm
1 = Alarm Enabled
O.Total[1].Acceleration
Decimal
BOOL
Enables the Acceleration alarm on output connected to channel 1. When
the absolute acceleration exceeds the Acceleration Alarm value, this
alarm is set.
0 = No Alarm
1 = Alarm Enabled
O.Total[1].Control
Binary
SINT
O.Total[1].Reset
Decimal
BOOL
O.Total[1].Load
Decimal
BOOL
O.Total[1].ProverEnable
Decimal
BOOL
Enables the prover operation on output connected to channel 1. Once this
bit is enabled, the module waits for output Z
0
to energize before
beginning prover operations.
0 = Prover operation is disabled
1 = Prover operation is enabled
O.Total[1].FillEnable
Decimal
BOOL
Enables the filling operation on output connected to channel 1.
0 = Fill operation is disabled
1 = Fill operation is enabled.
O.Total[1].FillStart
Decimal
BOOL
Begins filling operation when Fill Enable is enabled on output connected
to channel 1.
0 = Do not begin filling
1 = Begin filling
O.Total[1].FillHold
Decimal
BOOL
Holds/pauses filling operation on output connected to channel 1.
0 = Continue filling operation
1 = Hold/pause filling operation
O.Total[1].RollOverValue
Decimal
DINT
Sets the user-defined rollover value on output connected to channel 1.
Range of 0 - 2,147,483,647
O.Total[1].CombinedCorrectionFactor
Float
REAL
Unitless factor that is multiplied by Gross Rate with results shown as
NetRate of channel 1.
This value must be set to 1.0 when not used or gross rate will be 0.
Calculation Type must be set to 0 to use this factor.
O.Total[1].BaseTemperature
Float
REAL
Temperature in °F of output connected to channel 1.
O.Total[1].FlowingTemperature
Float
REAL
Temperature in °F of output connected to channel 1.
Table 16 - Configurable Flowmeter Module Output Tags
Name
Style
Data Type
Definition