Chapter 5 Configure the Configurable Flowmeter Module
5. Use ladder logic and a message instructions to send the new
configuration to your module, see
I.Status[0].Acceleration
Float
REAL
Displays acceleration on channel 0 as calculated by
using AccelCalculation samples
I.Status[0].GrossVolume
Float
REAL
Total Counts during each Sample/K-factor x Meter
Factor as occurs on channel 0
I.Status[0].NetVolume
Float
REAL
Total Counts during each Sample/K-factor x
MeterFactor x CCF) as occurs on channel 0
I.Status[0].GrossRate
Float
REAL
Total Counts in Meter Sample/ (K-factor x Sample
Interval) x Meter Factor as occurs on channel 0
I.Status[0].NetRate
Float
REAL
Total Counts in Meter Sample/ (K-factor x Sample
Interval) x Meter Factor x CCF as occurs on channel 0
I.Status[0].ProverTotal
Float
REAL
Corrected/compensated volume received on Channel 0
during prover cycle.
Prover total resets when the ProverEnable transitions
from 0-1.
Prover total concurrently accumulates with net volume,
and must be saved if subtracted from the NetVolume for
single and multiple prover verifications.
I.Ch0AccelerationAlarm
Decimal
BOOL
Displays whether acceleration alarm was set on channel
0
0 = alarm was not set
1 = alarm was set
I.Ch0OverspeedAlarm
Decimal
BOOL
Displays whether overspeed alarm was set on channel 0
0 = alarm was not set
1 = alarm was set
I.Ch0OverrangeAlarm
Decimal
BOOL
Displays whether overrange alarm was set on channel 0
0 = alarm was not set
1 = alarm was set
I.Ch0OverflowAlarm
Decimal
BOOL
Displays whether overflow alarm was set on channel 0
0 = alarm was not set
1 = alarm was set
(1) Additional Digital Filter options are now defined for Major Rev 3 and later in
.
Table 8 - Tag Changes Required for Totalizer Mode Using Prover Function
Name
Style
Data Type
Definition
Enter This
Value