SMPTE Configuration
Next, we will setup the SMPTE interface in the
SMPTE
Configuration
screen. You can access this screen by selecting
Binloop
!
SMPTE
!
Configuration…
or by clicking on the
icon.
Even though there is only one trigger at the start, we’ll have the
SMPTE clock run synchronous to the video. Select
29.97
as the
frame rate and enable the
Genlock To Video
option. Make sure
“Start Automatically on Power Up”
is checked. Uncheck
“Loop SMPTE at End Time”
to make sure that the trigger is
only executed once.
Now, the only thing left to configure is the range of time that the
SMPTE interface will generate. First, set the
Preroll Time
to
00:59:55.00
and the
Start Time
to
01:00:00.00
. Because we
only have one trigger, to loop continuously, SMPTE End Time is
not relevant.