51
5.3.
S
WITCHING ON
5.3.1.
F
IRST START UP
First conference system CS5 has to be installed and commissioned. It is possible to start
to connect computer based controlling only after programming all the delegate units and
functionally checking the complete system and its error-free operation. For this end first the
Basic Unit (BU) of the conference system should be switched off.
Switch on the controlling computer, on which controlling program
CS5 Confer
Control
had been installed already previously according to the contents of Section
«3.
Installation»
. It is not needed to start the controlling program itself for the time being.
Connect the «USB» cable delivered for the system to both the computer and the basic
unit (BU) of the conference system, then switch on the power supply unit.
At this point wait until the system synchronize itself, which is indicated by the
termination of the flashing of the yellow LEDs labeled as
«REMOTE»
and
«NOM LIMIT»
that are located on the front panel of the basic unit (BU). At the same time the yellow LED
labeled as
«POWER»
has to be on continuously.
After this Windows detects the new hardware and requests the driver program of the
new device, which is located in library
«usb2xxxx»
of the installation CD. This has to be
given as the access path for installing the driver.
The operation described in the previous paragraph has to be repeated once again.
Windows communicates that
«New device is ready for being used »
, if installation has
been successful.
Subsequently controlling program
CS5 ConferControl
may be loaded. The information
that should be known in respect of managing this program are included in section
«4.
Description of the controlling program»
.
In case controlling is executed through the
«SERIAL»
port, there is no need to install the
driver.
Attention!
Connecting the serial cable is permitted only in the switched off status of the
conference system and of the controlling computer.
5.3.2.
S
WITCHING ON AND OFF SEQUENCE
When switching on and off the conference system equipped with computer based
controlling that had been already fully installed and commissioned previously, the following
sequence must be followed step by step:
Switching on
•
Switch on the conference system
•
Wait until the system synchronize itself
•
Switch on the computer
•
Load controlling software
CS5 ConferControl
Switching off
•
Close and exit controlling software
CS5 ConferControl
•
Switch off the computer
•
Switch off the conference system