5-2
PERFORMANCE DATA & PRESSURE CURVES
SM DLF 1-A.1 GB
5.1.3 Heating
ID COIL ENTERING AIR DB TEMPERATURE [°C]
OD COIL ENTERING AIR
DB/WB TEMPERATURE
[°C]
DATA
15
20
25
-15/-16
TC
2.16
2.01
1.86
PI
0.52
0.58
0.63
-10/-12
TC
2.41
2.26
2.11
PI
0.63
0.68
0.74
-7/-8
TC
2.59
2.44
2.29
PI
0.71
0.76
0.82
-1/-2
TC
2.68
2.53
2.38
PI
0.78
0.83
0.88
2/1
TC
2.75
2.59
2.44
PI
0.82
0.87
0.92
7/6
TC
3.55
3.40
3.25
PI
0.82
0.87
0.92
10/9
TC
3.75
3.60
3.44
PI
0.87
0.92
0.97
15/12
TC
3.94
3.79
3.64
PI
0.91
0.97
1.02
15-24
TC
85 - 105 % of nominal
(Protection Range)
PI
80 - 120 % of nominal
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OD –
Outdoor
5.1.4
Capacity Correction Factors (Heating)
Heating Capacity Ratio Vs. Outdoor Temperature
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
-20
-15
-10
-5
0
5
10
15
Outdoor WB Temperature [deg C]
Capacity Factor
Summary of Contents for Multi Split DUO 50 DCI
Page 14: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit DCI 25 35 50 4 3 Outdoor Unit DCI 60...
Page 15: ...4 3 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 4 Outdoor Unit DCI 72Z...
Page 48: ...7 5 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 72Z Cooling DCI 72Z Heating...
Page 96: ...15 8 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 8 Outdoor Unit DCI 50...
Page 98: ...15 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 10 Outdoor Unit DCI 60...