16-8
APPENDIX A
SM DLF 1-A.1 GB
OPERATION
OPERATION
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN SPEED selector to the
position . A microcomputer automatically controls
the fan speed when the AUTO mode is selected.
When the air conditioner starts operating, the
difference between the room temperature
and the set temperature is detected by the
microcomputer which then automatically switches
the fan speed to the most suitable level.
NOTE
In FAN Only mode the fan speed is adjusted
automatically as in cooling mode.
WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
TEMPERATURE IS
FAN SPEED
Cooling and
dehumidifying
modes:
2 °C and over
High
Between 2 and 1 °C
Medium
Below 1 °C
Low
Heating mode:
2 °C and over
High
Below 2 °C
Medium
The above mentioned data make reference
to the conditioner operating when the sensor
on the remote control unit is ON. If the sensor
on the indoor unit is being used then actual
operation will slightly differ from that described
in the above tables.
MANUAL
If you want to manually adjust speed just set the
FAN SPEED selector as desired.
Each time the button is pressed, the fan speed is
changed in sequence:
SLEEP MODE
The SLEEP mode enables you to save energy.
1. Set the MODE selector to cool, dry or heat.
2. Press the SLEEP button.
3. The
mark appears on the display. Press
the SLEEP button again to release the SLEEP
function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or
heat the room to the set temperature, and
then the thermostat will make the unit pause.
After about 1 hour, the air conditioner will
automatically reset the set temperature as
follows (also refer to graphs).
OPERATING MODE
SET TEMPERATURE CHANGE
Heating
Lowered by 1 °C
Cooling and Dehumidifying
Raised by 1 °C
When the room temperature reaches the new
set value, the thermostat will cause the unit to
pause. After about 1 hour the temperature will be
raised by 1 °C in cooling, or lowered by 1 °C in
heating. This enables you to save energy without
sacrificing your comfort.
Setting temperature Room temperature
Setting temperature Room temperature
COOLING AND DEHUMIDIFYING
1 hour 1 hour
TIME
1 hour 1 hour
TIME
HEATING
(Lo) (Med) (Hi) (AUTO)
Summary of Contents for Multi Split DUO 50 DCI
Page 14: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit DCI 25 35 50 4 3 Outdoor Unit DCI 60...
Page 15: ...4 3 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 4 Outdoor Unit DCI 72Z...
Page 48: ...7 5 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 72Z Cooling DCI 72Z Heating...
Page 96: ...15 8 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 8 Outdoor Unit DCI 50...
Page 98: ...15 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 10 Outdoor Unit DCI 60...
Page 100: ...15 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 12 Outdoor Unit DCI 72Z...