D) HOW TO CLEAR THE TIMER
1. Press the TIMER button to select the timer.
2. Press the CLEAR button if you want that every
timer operation will be cleared.
NOTE
If the procedure to set the timer is not
completed, by pushing the SET button,
within 15 seconds the timer operation will be
cancelled and the last set-up is restored.
Set vertical vanes to the front position during
COOLING/DRY operation if humidity is high.
If the vertical vanes are set to the left-most
or right-most position, condensation will form
around the air outlet and drip off.
Do not move the flap with your hands when the
air conditioner is running.
ADJUSTING THE AIR FLOW DIRECTION
HORIZONTAL (manual)
The horizontal air flow can be adjusted by moving
the vertical vanes to the left or right, as indicated
in the following figures.
VERTICAL (with remote control unit)
The remote control gives you the possibility to
control the flap in two way:
1. Push the
button to start the flap sweep. If
you push again the flap stops immediately.
2. Push the
button to move the flap step by
step.
NOTES
The flap automatically closes when the unit is
off.
During the heating operation, the fan speed
will be very low and the flap will be in the
horizontal position until the air being blown
out of the unit begins to warm. Once the air
warms up, the flap position and fan speed
change to the settings specified with the
remote control.
Use the FLAP button on the remote control to
adjust the position of the flap. If you move the
flap by hand, the factual flap position and the
flap position on the remote control may no longer
match. If this should happen, shut off the unit,
wait for the flap to close, and then turn on the
unit again; the flap position will now be normal
again.
Do not have the flap pointed down during cooling
operation. Condensation may begin to form
around the air vent and drip down.
Summary of Contents for Multi Split DUO 50 DCI
Page 14: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit DCI 25 35 50 4 3 Outdoor Unit DCI 60...
Page 15: ...4 3 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 4 Outdoor Unit DCI 72Z...
Page 48: ...7 5 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 72Z Cooling DCI 72Z Heating...
Page 96: ...15 8 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 8 Outdoor Unit DCI 50...
Page 98: ...15 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 10 Outdoor Unit DCI 60...
Page 100: ...15 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 12 Outdoor Unit DCI 72Z...