16-46
APPENDIX A
SM DLF 1-A.1 GB
ELECTRICAL CONNECTIONS
ELECRICAL SPECIFICATIONS
POWER SUPPLY
1PH UNITS
NOMINAL VOLTAGE
LIMITS
POWER SUPPLY TO
OUTDOOR UNIT
POWER SUPPLY TO
INDOOR UNIT
1PH 230/50/1 198-264V
NOMINAL
CAPACITY
CIRCUIT
BRAKER
POWER
SUPPLY
CABLE
CIRCUIT
BRAKER
POWER
SUPPLY
CABLE
2.5-3.5kW
NOT APPLICABLE
16A
3x1.5mm
2
5.0-6.0kW
20A 3x2.5mm
2
20A 3x2.5mm
2
7.2kW 20A
3x2.5mm
2
NOT APPLICABLE
Electrical wiring and connections
should be made by qualified
electricians in accordance with
local electrical codes and
regulation. The air conditioner
units must be grounded.
The air conditioner units must be
connected to an adequate power
outlet from a separate branch
circuit protected by a time delay
circuit breaker, as specified on
unit's nameplate.
Voltage should not vary beyond ±
10% of the rated voltage.
1. Prepare the multiple wire cable
ends for connection.
2. Take away the Indoor/outdoor
cover and open the terminals,
take away the cable clamp
screw and turn over the cable
clamp.
3. Connect the cable ends to the
terminals of the indoor and
outdoor units.
4. Connect the other end of the
twin wire cable to the outdoor
unit twin wire terminal.
5. Secure the multiple wire power
cable with the cable clamps.
Summary of Contents for Multi Split DUO 50 DCI
Page 14: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit DCI 25 35 50 4 3 Outdoor Unit DCI 60...
Page 15: ...4 3 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 4 Outdoor Unit DCI 72Z...
Page 48: ...7 5 SOUND LEVEL CHARACTERISTICS SM DLF 1 A 1 GB DCI 72Z Cooling DCI 72Z Heating...
Page 96: ...15 8 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 8 Outdoor Unit DCI 50...
Page 98: ...15 10 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 10 Outdoor Unit DCI 60...
Page 100: ...15 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 15 12 Outdoor Unit DCI 72Z...