background image

OMZ-1000-HF (HFT)

Operation and Maintenance Instructions 

IMPORTANT!!!!! 

1. Read instructions thoroughly before operating!! 

2. After shipping the unit via courier or after rough handling such as falling off a shelf open cabinet by following 

step 1 of the cleaning instructions. Check to make sure the center screen of the generator plate has not moved 

out of place. Once this has been checked the plate rack may be reinstalled and the unit is ready for use. 

CAUTION, THIS OZONE GENERATOR OPERATES AT 4000-5000 VOLTS AC 

DISCONNECT POWER BEFORE OPENING TO SERVICE 

SPECIFICATIONS FOR OMZ-1000-HF (HFT) Ozone Generator 

Maximum output

             1,000 mg/hr (1 ozone plate) / upgradable to 3,600 mg/hr (5 ozone plates)

Fan (rated cfm)

               105 cfm 

Filter

                                1 Cleanable foam filter 

Cabinet material

              PVC outer cabinet with stainless steel inner chassis 

Generation method

          Corona discharge 

Weight and size

               10.5-lb 21" long x 5" wide x 6-5/8" height (including handle) 

INTRODUCTION 

This line of ozone generators are designed for various uses at varying output levels. This ozone generator can be 

used for many uses such as deodorizing cars homes as well as oxidizing many organic contaminants. 

WARRANTY 

The OMZ-1000HF(HFT) is warranted against defects in materials and workmanship for a period of four years from 

date of purchase. Liability is limited to parts and labor only. Shipping is the sole responsibility the customer. OZSL is 

not liable for damage caused by shipping, misuse, neglect or lack of regular maintenance. 

LIABILITY 

OZSL assumes no responsibility for any damage done to items from the use or miss use of any product sold or 

manufactured by OZSL. It is the customers responsibility to test materials prior to use and to ensure that the 

procedure and installation technique they are using is correct for the application. 

HEALTH AND SAFETY 

Ozone can be an irritant and a powerful oxidizing agent. As with most all products, ozone is dangerous only when 

used improperly, as such it is important to follow safe usage guide lines. 

*When doing a shock treatment, no people plants or pets/animals may be in the room when the unit is running.* 

The room should not be reentered until all ozone has been depleted unless proper breathing respirators are used. 

MAINTENANCE FREQUENCY 

Under heavy duty use or severely polluted areas, The ozone generator should be inspected and cleaned if 

necessary every 2 to 3 weeks for fine dust or oily residue collecting on generator surfaces or plates. Light duty 

use requires cleaning every 2 to 6 months depending on the severity of pollution and the humidity level of the 

feed air. In dirty and humid conditions cleaning can be as often as 2-4 weeks. 

DESCRIPTION OF OZONE GENERATOR 

These ozone generators produce ozone by corona discharge, converting normal oxygen to ozone gas which is a 

very strong oxidizing agent used to destroy odors and other organic contaminants.  This model comes from the 

factory with 1 plate, producing up to 1000mg/hr, and can be upgraded by adding as many as 4 additional plates to a 

max of 3,600mg/hr.

PLACEMENT OF UNIT 

This ozone generator is designed as a portable commercial deodorizing device. It uses 120VAC for North America, 

and 220-240VAC for European countries etc. European models come with an IEC connector and it is up to the 

customer to supply the proper cord (this can be acquired at any computer shop). 

Please note the following points when placing the unit. 

-Place on a flat solid surface such as a table or shelf. Do not place on rug flooring to reduce dust entering the unit 

-Do not place in an area where the unit could be splashed with water, moisture or in an area that it could get 

flooded with water. 

-Ensure that the unit gets proper fresh air flow. Do not obstruct the incoming or outgoing air from the unit. 

-DO NOT USE IN VICINITY OF COMBUSTIBLE GASSES!! 

-Humidity levels higher than 75% should be avoided as it will cause the unit to wear excessively fast and will 

require cleaning much more often. 

-If used in temperatures below freezing, ensure that condensation inside the unit does not occur. 

-Set the unit in an area where it will provide the best ozone distribution. 

-The use of circulation fan will greatly increase the efficiency of the treatment. 

-If the ozone generator being used is large enough to treat the whole house, the air handling system can be used 

to distribute the ozone, just point the ozone generator into the return air duct. 

Summary of Contents for OMZ-1000-HF

Page 1: ...s running The room should not be reentered until all ozone has been depleted unless proper breathing respirators are used MAINTENANCE FREQUENCY Under heavy duty use or severely polluted areas The ozone generator should be inspected and cleaned if necessary every 2 to 3 weeks for fine dust or oily residue collecting on generator surfaces or plates Light duty use requires cleaning every 2 to 6 month...

Page 2: ... inline with the Hi Low switch This timer is designed to allow the user to turn on the ozone generator and have it turn off after a given amount of time or run it continuously the word HOLD means continuous To use the timer first make sure the switch is in the Hi or Low position a To turn the timer on to constantly run simply press and hold the button for a couple seconds the top green LED will li...

Page 3: ... RE ASSEMBLY 7 Reinstall plates by first using a screw driver to separate the tight ring springs as shown Then slip the plate in between the springs making sure that the spring does not go up in the middle of the plate as shown 8 Re install the plate hold down bar as shown in the step 4 picture Re install the HV clamp making sure that all the HV wires from the plates are clamped tight 9 Please not...

Page 4: ...d screens If using an oven set the temperature at about 200 F and place the mica and screens on the middle rack for approximately 1 2 hours If there is no rush or you do not have access to an oven place the mica and screens in a very warm dry place such as on an operating base board heater to dry overnight or if it must air dry leave it dry for several days with good air flow 5 Once all the Mica a...

Reviews: