60
Aibot X6 V2, Operation
3.8.4
Ultrasonic Sensor Failure
Abnormal
Procedures
Identification
•
Voice Response: “Distance measurement failure!”
•
The Aibot X6 V2 descends below the defined minimum altitude.
•
Automatic takeoff and automatic landing are not working.
Recommended Procedure
CAUTION
Automatic takeoff and landing without ultrasonic sensors
In case of a voice response: “Distance measurement failure!”, the automatic
landing and automatic takeoff mode is working without the use of ultrasonic
sensors. Be aware of a faster descent speed for an automatic landing.
It is necessary to assist the landing procedure in case of an automatic landing
or failsafe procedure.
Prevention
•
Operation according to normal procedures.
•
Inspection and cleaning of the ultrasonic sensors according to the check-
lists.
•
Do not cover the field of view of the ultrasonic sensors with cables or other
objects.
Description
Condition/Action
RC
Assist Mode
OFF
X6
Altitude
Control the altitude manually with the
throttle joystick.
X6
Landing
Follow the manual landing procedure
as normal.