50
Aibot X6 V2, Operation
3.6.6
After Landing (Assist Mode)
Normal Procedures
3.6.7
Dynamic Position Hold
Normal Procedures
This procedure can be activated during flight execution. The Aibot X6 V2 will
automatically hold the current position.
Description
Condition/Action
X6
LiPo batteries
Plug off
RC
Power
OFF
X6
Motor temperature
Maintain a motor cool down phase of
at least 5
minutes in a shady (cool)
place. At temperatures above 25
°C a
cool down phase of at least
15
minutes is recommended. The
cool down phase may vary and
depends on many factors.
Description
Condition/Action
RC
GPS
PH
RC
POI
OFF
RC
Flight Plan
OFF
RC
Care Free
As required
RC
Assist Mode
ON
RC
Telemetry
Check regularly
GE
Airspace
Clear and safe
X6
Altitude and Distance
Adjust to remaining battery power
and flight configuration.