Aibot X6 V2, Operation
21
3
Operation
3.1
General ground handling
3.1.1
Charging the Batteries
Balance the
batteries
To ensure a safe use, each cell must be balanced within the battery. Testing
can be done with the included battery tester. When connected, the voltage of
each cell is displayed in a row. Every cell must have a voltage of at least 4.0
volts. The difference between the individual cells must not be more than 0.08
volts. For example:
•
cell 1: 4.15 V
•
cell 2: 4.19 V
•
cell 3: 4.17 V
•
cell 4: 4.14 V
•
cell 5: 4.18 V
•
total: 20.83 V
Charging the
batteries
Read and follow all instructions provided by the manufacturer of the battery
charger and the batteries.
A battery charger for the LiPo batteries is included in your delivery. The battery
charger allows the charging of four batteries at once. A power supply unit
powers the battery charger. All needed cables are included.
CAUTION
Risk of short circuit
Precautions:
First attach the charging cable to the battery charger, then attach the charging
cable to the battery.
Never leave the batteries unattended while charging.
To charge the batteries:
1) Connect the power supply unit to the power source.
2) Connect the battery charger to the power supply unit.
3) Attach the charging cable and the balancer adapter to the battery charger.
4) Attach the battery to the balancer adapter and charging cable.
5) Switch on the power supply unit.
6) Check if output voltage of the power supply unit is set to 15 V.
7) Check the battery charger settings: "LiPo Balance, 5.0 A, 18.5 V (5S)".
8) Press and hold the start button for a short time to start the charging
process.
WARNING
Overheating Batteries
Risk of explosion or fire.
Precautions:
•
Protect batteries against high temperatures.
•
Always use the provided battery charger.