56
Aibot X6 V2, Operation
3.7.4
Manual Landing
Normal Procedures
On ground:
DANGER
Crash due to downwash near ground.
Downwash of the own rotor blades can lead to turbulences. Risk of serious
injuries and damages because of falling device.
Precautions:
•
Be aware of the downwash of your own rotor blades when flying near
ground.
3.7.5
Manual Abort Landing
Normal Procedures
3.7.6
After Landing (Manual Mode)
Normal Procedures
Description
Condition/Action
GE
Landing site
Clear and safe
RC
Throttle Joystick
To descent, slowly pull the throttle
joystick towards you to decrease the
motor power. Control position and
heading manually.
Description
Condition/Action
RC
Throttle Joystick
When touched the ground fully pull
the throttle joystick towards you.
RC
Motor
OFF
Description
Condition/Action
RC
Throttle joystick
To abort the landing, push the
throttle joystick away from you to
increase the motor power. Control
position and heading manually.
Description
Condition/Action
X6
LiPo batteries
Plug off
RC
Power
OFF
X6
Motor temperature
Maintain a motor cool down phase of
at least 5
minutes in a shady (cool)
place. At temperatures above 25
°C a
cool down phase of at least
15
minutes is recommended. The
cool down phase may vary and
depends on many factors.