10. Loading
The internal temperature must be monitored for 4-5
hours after the cabinet is commissioned.
note
• Please wait until the required product storage tem
-
perature has been reached before storing products
inside.
CAUTION
Hands can be frozen in the freezer area
while loading the cabinet. You must there
-
fore use protective gloves.
The cabinet should only be loaded as far as the front
edge of the bottom compartment (base tray/panel) or
the suspended shelves (display/shelves). Arrange the
products carefully so that they cannot fall out acciden-
tally when the customer removes one.
Air inlets and outlets must not be blocked.
note
• Be sure to observe the maximum loads for each kind
of storage rack, as shown in the following table.
Rack/Segment
maximum
load [kg]
Display/shelf 26
(max. 2 per segment)
Base tray/panel
26
The maximum overall loads for each kind of cabinet
are therefore:
Cabinet model
maximum overall
load [kg]
KINLEY 210 (–)
KINLEY 210 XL (–)
234
KINLEY 250 (–)
KINLEY 250 XL (–)
312
11. Maintenance, defrosting,
cleaning
11.1 Maintenance
The cabinets are generally maintenance-free. Howev-
er, as described in the following sections, they must be
defrosted and cleaned.
11.2 Defrosting and cleaning
The cabinet may become dirty if used daily. The op-
erator must therefore defrost and clean the cabinet
manually at regular intervals for reasons of hygiene.
Cleaning frequency
: Once or twice a year.
note
• Do not scrape or chip off the layer of ice and frost
with sharp objects or tools. Risk of damaging the
interior walls.
WARNING
Risk of ignition from sparks As a result of po-
tential leaks in the R-290 refrigeration sys-
tem, sparks from a vacuum cleaner or other
electrical cabinets may cause the mixture of
gas and air that may form to ignite acciden-
tally.
➤
Remove the condensation from R-290
cabinets only with a dry towel or a
sponge.
➤
Only use wet vacuum cleaners or electri-
cal appliances with an explosion protec-
tion marking inside the refrigerated cabi-
net.
The following table shows a step-by-step guide to the
complete defrosting process with an electronic con-
troller:
Carrying out a complete defrosting procedure
electronic controller
1. Transfer the products to other cabinets.
2. Switch off the cabinet.
3. Open the glass doors so that the cabinet can
defrost more effectively.
4. Remove all loose fittings and accessories (air
ducts, base grids, product grids, etc.).
5. Remove condensation. Either with a wet vacuum
cleaner (
→
bear in mind the warning for cabinets
with R-290 refrigerant), or by drying it up with a
cloth or sponge.
6. Wipe the cabinet dry and clean the interior.
7. Close the condensation drain again if there is
one in place.
8. Reinstall the parts and accessories that were
removed beforehand.
9. Close the doors again correctly.
10. Switch the cabinet on again.
Display shows the actual temperature.
Instruction
Summary of Contents for Kinley
Page 2: ...2 ...
Page 4: ...4 ...
Page 6: ...6 ...
Page 42: ...42 DE EN IT FR ES PT NL DA FI SE NO SL HR CS SK PL ET LT LV HU RU RO EL TR BG ...
Page 122: ...122 DE EN IT FR ES PT NL DA FI SE NO SL HR CS SK PL ET LT LV HU RU RO EL TR BG ...
Page 130: ...130 DE EN IT FR ES PT NL DA FI SE NO SL HR CS SK PL ET LT LV HU RU RO EL TR BG ...
Page 138: ...138 DE EN IT FR ES PT NL DA FI SE NO SL HR CS SK PL ET LT LV HU RU RO EL TR BG ...
Page 146: ...146 DE EN IT FR ES PT NL DA FI SE NO SL HR CS SK PL ET LT LV HU RU RO EL TR BG ...
Page 154: ...154 ...
Page 162: ...162 ...
Page 170: ...170 ...
Page 178: ...178 ...
Page 186: ...186 ...
Page 194: ...194 ...
Page 202: ...202 ...
Page 210: ...210 ...
Page 218: ...218 ...
Page 226: ...226 ...
Page 234: ...234 ...
Page 242: ...242 ...
Page 250: ...250 ...
Page 258: ...258 ...
Page 266: ...266 ...
Page 267: ...267 ...