© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
57
Shade / Blackout Curtain Mode
This mode is designed to control shade curtains and black-out curtains using the static position option.
Override positions for high light intensity, high temperature and weather alarms can also be configured to
actively adjust the position depending on conditions if desired. To enable a position option, turn on the ap
-
propriate switch and the settings will be shown.
Shade mode will reduce the %open position in the solar shading and temperature shading modes in an
effort to reduce solar radiation resulting in excess heat. Shading from high intensity light can reduce solar
heating or when the interior temperature is too high can help alleviate excess heat.
1. Solar Shading Set this option to limit the position based on light intensity.
If intensity is high, the shade will reduce %open to the selected position.
2. Light Sensor Select the sensor to read the light intensity.
3. Solar Position
Maximum %open position when limit is exceeded.
4. Solar Limit
Light intensity high limit; if reached, the position limit is activated.
5. Temperature Shading
Set this option to limit the position based on high temperature.
If temperature is high, the shade will reduce %open to the selected position.
6. Temperature Sensor
Select the sensor to read the temperature.
7. Temperature Position
Maximum %open position when limit is exceeded.
8. Temperature Limit
Temperature high limit; if reached, the position limit is activated.
2
3
4
6
7
8
1
5