Low Frequency Multiplexer Switch Modules
4
34980A User’s Guide
123
Example: Closing and opening Analog Bus relays
The following command
connects the Analog Buses to Bank 1 (via the Analog Bus relays on Bank
1) for a module in slot 3.
ROUTe:CLOSe (@3911,3912,3913,3914)
ROUTe:OPEN (@3911,3912,3913,3914)
The Analog Bus relays (numbered s911, s912, s913, etc.) on the MUX
modules are ignored if they are included in a range of channels.
An error will be generated if an Analog Bus relay is specified as the
first or last channel in a range of channels. For example, the following
command closes all valid channels between channel 30 (slot 1) and
channel 5 (slot 2). In addition, this command closes Analog Bus relay
911 on the module in slot 1 (Bank 1). Note that although the specified
range of channels includes the other Analog Bus relays, they are ignored
and are not closed by this command.
ROUTe:CLOSe (@1030:2005,1911)
Example: Querying channels for open or close state
The following command
returns a 1 (true) or 0 (false) state of channel 036 for a module in
slot 3.
ROUTe:CLOSe (@3036)
ROUTe:CLOSe? (@3036) !Returns a 1
ROUTe:OPEN? (@3036) !Returns a 0
Making Measurements
Example: Making voltage measurements
The following command configures
channels 9 and 10 in slot 4 for DC voltage measurements, triggers the
internal DMM to scan channels 9 and 10, and returns the reading.
The 1 V range is selected with 1 mV resolution.
MEASure:VOLTage:DC? 1,0.001, (@4009,4010)
Example: Making voltage measurements using INITiate and FETCh?
The following program segment shows how to use the
INITiate
command with the
CONFigure
and
FETCh?
commands. The
ROUTe:SCAN
command puts channels 3 and 8 (of a module in slot 1) into the scan list
(and redefines the scan list). The
INITiate
command scans the specified
channels, and then sends the readings to memory. The
FETCh?
command
transfers the readings from memory to the user.
CONFigure:VOLTage:DC 10,0.003,(@1003,1008)
ROUTe:SCAN (@1003,1008)
INITiate
FETCh?
Summary of Contents for Agilent 34980A
Page 1: ...Agilent Technologies Agilent 34980A Multifunction Switch Measure Unit User s Guide ...
Page 2: ......
Page 6: ......
Page 198: ...186 34980A User s Guide 5 Matrix Switch Modules ...
Page 210: ...198 34980A User s Guide 6 General Purpose Switch Modules ...
Page 216: ...204 34980A User s Guide 7 RF Multiplexer Switch Modules ...
Page 314: ...302 34980A User s Guide 11 4 Channel Isolated D A Converter with Waveform Memory Module ...
Page 322: ...310 34980A User s Guide 12 Multifunction Module with DIO D A and Totalizer ...