To make delay measurements automatically
You can measure the delay of signals connected to the oscilloscope’s input 1
and input 2 connectors when the Measurement/Storage Module is connected
to the oscilloscope.
Delay is measured from the user-defined slope and edge count of the signal
connected to input 1, to the defined slope and edge count of the signal
connected to input 2.
1
Adjust controls so that a minimum of 6 full cycles of the signals
connected to inputs 1 and 2 are displayed.
2
Press
Time
.
3
Press the
Next Menu
softkey until the
Define Thresholds
softkey is
displayed on the far left side.
4
Press the
Define Delay
softkey.
A softkey menu with five softkey choices appears. Four of them are related
to defining the delay measurement.
•
Chan 1
Selects the channel 1 slope (rising or falling) where the delay
measurement will START. Threshold level is always 50%.
•
Edge
Selects the edge count (from 1 to 5) where the delay measurement
will START.
•
Chan 2
Selects the channel 2 slope (rising or falling) where the delay
measurement will STOP. Threshold level is always 50%.
•
Edge
Selects the edge (from 1 to 5) count where the delay measurement
will STOP.
•
Previous Menu
Returns you to the previous softkey menu.
5
Use the displayed softkeys to specify the starting (from) and stopping
(to) slope and edge count. Transition point (measurement threshold
level) is fixed at 50%.
6
Press the
Previous Menu
softkey.
Operating the Measurement/Storage Module
To make delay measurements automatically
2–19
Summary of Contents for 54657A
Page 5: ...Installation 1 Reference Information 3 Operating the Measurement Storage Module 2 Index v ...
Page 6: ...vi ...
Page 8: ...3 Reference Information Operating Characteristics 3 3 Index Contents Contents 2 ...
Page 9: ...1 Installation ...
Page 16: ...1 8 ...
Page 17: ...2 Operating the Measurement Storage Module ...
Page 73: ...3 Reference Information ...
Page 80: ...3 8 ...
Page 87: ...Voltage Time Cursors Press this key to obtain this menu ...
Page 88: ...Print Utility Trace Trace Press this key to obtain this menu ...