![Aerotech Automation1 XL5e Hardware Manual Download Page 90](http://html1.mh-extra.com/html/aerotech/automation1-xl5e/automation1-xl5e_hardware-manual_2863032090.webp)
Isolated Signals
This output signal is a fully-isolated 5-24V compatible output capable of sourcing or sinking current.
This output is normally open and only conducts current when a PSO fire event occurs.
The PSO Isolated Outputs are overload protected and will turn off if the maximum output current is
exceeded.
Figure 3-10:
PSO Output Sources Current
Figure 3-11:
PSO Output Sinks Current
TTL Signals
This output signal is a 5V TTL signal which is used to drive an opto coupler or general purpose TTL
input. This signal is active high and is driven to 5V when a PSO fire event occurs.
Figure 3-12:
PSO TTL Outputs Schematic
3.5. Position Synchronized Output Interface [-EB1]
XL5e Hardware Manual
90
www.aerotech.com
Summary of Contents for Automation1 XL5e
Page 1: ...Revision 1 01 Automation1 XL5e High Performance Linear Digital Drive HARDWARE MANUAL...
Page 22: ...Figure 1 4 Dimensions EB1 1 2 2 Dimensions XL5e Hardware Manual 22 www aerotech com...
Page 63: ...Figure 2 32 PSO Interface XL5e Hardware Manual 2 5 Auxiliary I O Connector www aerotech com 63...