7
Both the BATTERY MENU and DATE/TIME are sub-menus selected by pressing
the right arrow key when the cursor is next to that item. The BATTERY MENU
permits setting BATTERY SAVER ON/OFF, BATTERY TYPE, and BATTERY
MA-HR. The DATE/TIME menu is for setting the current date and time. See
Section 2 in this manual for full details on both sub-menus.
Trace Key opens a menu for viewing and making changes in the
display plot settings, turning on MICRO FAULT detection, eliminating the test
leads distance (CABLE NULL), and activating a noise filter. The Trace key’s
menu is shown in Figure 1-6.
Figure 1-6
Memory key opens a menu for saving and recalling traces. Saving a
trace opens a sub-menu for entering the trace name and automatically saves the
date/time with the trace data. Recall opens a list of saved test results. Recalling a
trace resets the instrument to the recalled trace’s settings. This makes all stored
traces a stored instrument set up as well. After recalling one or more traces,
selecting PRIOR SETTINGS will restore the TDR to original settings before the
recalls. The Memory key’s menu is shown in Figure 1-7.
Figure 1-7