Chapter 5. Configuration Menu
5-26
TDU 120e User Manual
61202156L2-1
NET/DATA FAIL
Backup occurs on the same conditions as
NET FAIL
plus loss of data transitions on the data the Nx56/64
receives from the network.
Pattern Verify
Selects whether or not the DBU will use its pattern
generator and receiver to authenticate backup
attempts. When the local and remote units are both
Nx/DBUs, set to
E
NABLE
; otherwise set to
D
ISABLE
.
Choices:
E
NABLE
,
D
ISABLE
Backup Delay
Selects the time allowed to elapse between the net-
work going into alarm or no data transmissions and
the backup beginning.
Choices:
1
SEC
, 3
SEC
, 10
SEC
, 30
SEC
, 1
MIN
, 5
MIN
,
10
MIN
Restore Delay
Selects the time that elapses between the network
going out of alarm or data being received and the
backup call being taken down. If
N
EVER
is selected,
the user must deactivate the backup mode.
Choices:
1
SEC
, 3
SEC
, 10
SEC
, 30
SEC
, 1
MIN
, 5
MIN
,
10
MIN
,
NEVER
Retry Delay
Selects the time between redialing the external DCE
after failed dial attempts.
Choices:
10
SEC
, 30
SEC
, 1
MIN
, 5
MIN
, 10
MIN
Num Retries
Selects the number of times the DBU will attempt to
redial if unable to connect.
Choices:
N
ONE
,
U
NLIMITED
,
3
TIMES
,
10
TIMES
.
Summary of Contents for 1202155L1
Page 1: ...TDU 120e User Manual Part Number 1202156L2 1202155L2 September 2001 61202156L2 1C...
Page 20: ...Table of Contents xx TDU 120e User Manual 61202156L2 1...
Page 22: ...List of Figures xxii TDU 120e User Manual 61202156L2 1...
Page 24: ...List of Tables xxiv TDU 120e User Manual 612022156L2 1...
Page 42: ...Chapter 2 Installation 2 12 TDU 120e User Manual 61202156L2 1...
Page 92: ...Chapter 5 Configuration Menu 5 30 TDU 120e User Manual 61202156L2 1...
Page 108: ...Chapter 7 Test Menu 7 12 TDU 120e User Manual 61202156L2 1...
Page 116: ...Chapter 8 Remote Management Menus 8 8 TDU 120e User Manual 61202156L2 1A...
Page 124: ...Appendix A Understanding SNMP A 8 TDU 120e User Manual 61202156L2 1...