Chapter 5. Configuration Menu
61202156L2-1
TDU 120e User Manual
5-25
Dial Backup Config
Under
DBU C
ONFIG
, the menu items are:
Backup Mode
In a backup condition, both ends of the circuit must
detect backup conditions before backup is activated.
One DBU is set to
O
RIGINATE
and the other to
A
NSWER
. Upon a network failure, only the Originate
DBU initiates backup by dialing the
A
NSWER
END
.
Once called, the
A
NSWER
DBU
goes into backup
mode only if a backup condition is detected. This is
ideal for controlling where calls originate.
Choices:
D
ISABLE
,
O
RIGINATE
,
A
NSWER
Backup On
Selects the conditions that cause the Nx/DBU to ini-
tiate Backup.
NET FAIL
Backup occurs on
R
ED
A
LARM
,
Y
ELLOW
A
LARM
,
B
LUE
A
LARM
and
LOS
.
Table 5-1. Normal Mode of Operation
RTS
V.54
Loopback
511 TST
ON
Self Test
Active
Netwk Test
Active
No DS0
Mapped
Network
Alarm
CTS
Follows
OFF
OFF
OFF
OFF
OFF
DCD
—
—
OFF
—
OFF
OFF
DSR
—
OFF
OFF
OFF
OFF
—
Where “—” = don’t care
Force On = On under all conditions
This table indicates conditions which cause the
P
ORT
C
ONTROL
S
IGNALS
to be deactivated.
Summary of Contents for 1202155L1
Page 1: ...TDU 120e User Manual Part Number 1202156L2 1202155L2 September 2001 61202156L2 1C...
Page 20: ...Table of Contents xx TDU 120e User Manual 61202156L2 1...
Page 22: ...List of Figures xxii TDU 120e User Manual 61202156L2 1...
Page 24: ...List of Tables xxiv TDU 120e User Manual 612022156L2 1...
Page 42: ...Chapter 2 Installation 2 12 TDU 120e User Manual 61202156L2 1...
Page 92: ...Chapter 5 Configuration Menu 5 30 TDU 120e User Manual 61202156L2 1...
Page 108: ...Chapter 7 Test Menu 7 12 TDU 120e User Manual 61202156L2 1...
Page 116: ...Chapter 8 Remote Management Menus 8 8 TDU 120e User Manual 61202156L2 1A...
Page 124: ...Appendix A Understanding SNMP A 8 TDU 120e User Manual 61202156L2 1...