background image

Table of Contents 

THANK YOU 

Safety Information 

USE AND CARE GUIDE 

   

DIGITAL MULTIMETER

 

We appreciate the trust and confidence you have placed in Commercial Electric through 

the purchase of this digital multimeter. We strive to continually create quality products

 designed to enhance your home. Visit us online to see our full line of products available 

for your home improvement needs. Thank you for choosing Commercial Electric!

Questions, problems, missing parts? Before returning to the store, 

                          call Home Depot Customer Service 

 

1-877-527-0313

 

HOMEDEPOT. COM

 

Please read this manual carefully and pay attention to related safe working standards 
before using this meter. Protection provided by the instrument will be impaired if 
used in a manner not specified by the manufacturer.

Table of Contents ...

2

.........................

Safety Information  

2

.........................

Warranty  .........................................3
Pre-Operation  ................................. 4

Symbol

 

Definition

 

CAT II

This product conforms to UL STD. 61010-1, pollution 2.

Measurement category II, which is for measurements 
performed on circuits directly connected to the 
low voltage installation.

The fuse must be replaced with the rating specified 
in this manual.

Indicates important safety 

 

information, refer to the operating manual.

  

Dangerous

 

voltage

 

may

 

be

 

present

Double Insulation, Protection Class ll.

 

Operation

 

 

7

.......................................

Maintenance ..................................

 

 

9

Care and

 

Cleaning

 

.......................

 

10

 

2

Item 

119

 

701

 

 

Model 

MAS830B

 

Earth (ground).

Summary of Contents for 119 701

Page 1: ... manual carefully and pay attention to related safe working standards before using this meter Protection provided by the instrument will be impaired if used in a manner not specified by the manufacturer Table of Contents 2 Safety Information 2 Warranty 3 Pre Operation 4 Symbol Definition CAT II This product conforms to UL STD 61010 1 pollution 2 Measurement category II which is for measurements pe...

Page 2: ... fingers behind the probe barriers while measuring WARNING Always be careful when working with voltages above 60V DC or 30V AC rms WARNING Never use the meter to measure voltages that might exceed 600V above earth ground in Category II installations CAUTION Before rotating the range selector to change functions disconnect test leads from the circuit under test CAUTION When carrying out measurement...

Page 3: ...50V rms For 200mV range and 600V DC or rms AC for other ranges Measuring Range 20uA 200uA 2mA 20mA 200mA Resolution 0 01uA 0 1uA 1uA 10uA 100uA Accuracy 3 rdg 15dgt 10A 10mA 1 5 rdg 10dgt 1 rdg 8dgt 1 rdg 8dgt 1 rdg 5dgt 1 rdg 5dgt DC CURRENT SPECIFICATIONS Additional Specifications Overload Protection mA jack F 250m A jack F 10A 250V fuse A 250V fuse and Measuring Range 200V 600V Resolution 100mV...

Page 4: ... leads G and H in series with the circuit Read current value on the LCD display A along with the polarity of the red lead G connection Connect the red test lead G to the VΩΩmA jack F and the black test lead H to the COM jack E For measurements between 200mA and 10A insert the red test lead H into the 10A jack D Operation Continued Set the rotary switch C to the desired ACV position Connect the red...

Page 5: ...to the anode of the diode to be tested and the black test lead H to the cathode of the diode The approximate forward voltage drop of the diode appears in the LCD display A If the connection is reversed a 1 is displayed in the LCD A Connect the red test lead G to the V ΩmA jack F and the black test lead H to the COM jack E Ω Maintenance WARNING Before you open the battery cover ensure that test lea...

Page 6: ...Questions problems missing parts Before returning to the store call Home Depot Customer Service 1 877 527 0313 HOMEDEPOT COM Retain this manual for future use ...

Page 7: ...idad 2 Garantía 3 Pre Funcionamiento 4 Funcionamiento 7 Mantenimiento 9 Cuidado y Limpieza 10 Información de Seguridad Por favor lea este manual cuidadosamente y preste atención a las normas de trabajo seguro relacionadas antes de utilizar este medidor La protección proporcionada por el instrumento será afectada si se utiliza de una manera no especificada por el fabricante Símbolo Definición CAT I...

Page 8: ...r a 10 segundos para cada medición y el intervalo de tiempo entre dos mediciones debe ser superior a cinco minutos PRECAUCION Antes de girar el selector de rango para cambiar las funciones desconecte las puntas de prueba del circuito bajo prueba NOTA Cuando la escala de valor a ser medida es desconocida antes de la medición coloque el selector de rango en la posición más alta PRECAUCION Al realiza...

Page 9: ...00Ω 1kΩ Precisión 1 0 rdg 5dgt 0 8 rdg 2dgt 0 8 rdg 2dgt 0 8 rdg 2dgt 0 8 rdg 5dgt Pre Funcionamiento Continuación ESPECIFICACIONES DEL PRODUCTO Rango de Medición 200mV 2V 20V 200V 600V Resolución 100uV 1mV 10mV 100mV 1V Precisión 0 5 rdg 3dgt 0 8 rdg 5dgt ESPECIFICACIONES DE VOLTAJE CC Especificaciones Adicionales Protección de Sobrecarga 250V rms Para el rango de 200mV y 600V CD o rms CA para ot...

Page 10: ...s puntas de prueba roja y negra G y H en serie con el circuito Lea el valor de la corriente en la pantalla LCD A junto con la polaridad de la conexión de la punta de prueba roja G Funcionamiento Continuación Conecte la punta de prueba roja G al conector VΩmA F y la punta de prueba negra H al conector COM E Ajuste el interruptor giratorio C a la posición deseada de VCA Conecte las puntas de prueba ...

Page 11: ...as o roturas visibles en la carcasa o el cable deje de usar el medidor inmediatamente PRECAUCION Para una protección continuada contra incendios reemplace el fusible de acuerdo con el voltaje y rangos de corriente especificados F1 250mA 250V a F2 10A 250V de acción rápida Si el icono de batería aparece en la pantalla LCD esto indica que la batería necesita ser reemplazada El fusible rara vez requi...

Page 12: ... Preguntas problemas piezas faltantes Antes de regresarlo a la tienda llame a Servicio al Cliente de Home Depot 1 877 527 0313 HOMEDEPOT COM Conserve este manual para referencia futura ...