Summary of Contents for 60906

Page 1: ...00K 2000K Ohm Accuracy 200 200K Ohm 0 8 20 2000K Ohm 1 0 20 Sampling Rate 2 5 times Second Overload Protection Fast Acting 500mA 250V Fuse Operating Temperature Range 32 104 F Display I high 3 1 2 digii LCD Battery One 9 V included Weight 45 lb Features 29 1 2 Test Leads Transistor NPN and PNP Testing Function Battery Testing Function and Automatic Polarity and Zero Adjust Save This Manual You wil...

Page 2: ...eplaced by a qualified technician Do not use the tool if any switch does not operate properly SKU 69096 For replacement parts please call 1 800 444 3353 Page 3 15 Replacement_parts and accessories When servicing use only identical replacement parts Use of any Other parts will void the warranty Only use accessories intended for use with this tool Approved accessories are available from Harbor Freig...

Page 3: ...est range if the amperage is unknown Plug the red lead into the 1OA Top Jack Plug the black lead into the COM Bottom Jack Switch the Multimeter ON Carefully touch the exposed conductors with the tips ofthe probes to measure the amperage Note Amperage is always tested in series with the circuit under test 4 Read measurement Ifthe reading is less than 2AMPs switch the req lead to the VOmA Center Jac...

Page 4: ...he black to the negative terminal 4 The battery amperage under a load of 370 mn will be displayed to a resolution of 1mA 5 1 2 3 4 1 2 3 4 5 6 Nornial amperage For a standard 9V 6LR61 battery For a 1 5 V AA LR6 battery Mainte ance 25 mA 4mA Wipe unit with a slightly damp cloth using a light detergent Do not use solvents or abrasives J Remove battery if not in use for I ng periods Store unit in a d...