Chapter 5.  Configuration Menu

61202156L2-1

TDU 120e  User Manual

5-7

Network Timed

The network is the source of timing. The received 
data clocking is looped back to the network, where it 
is used to determine the transmission timing. This 
option is also referred to as loop timed as the trans-
mission clock is derived from the received clock. See 
Figure 5-4.

Figure 5-4.  Network Timed Clock Source

INTERNAL

OSCILLATOR

SECONDARY
INTERFACE

OPTION CARD

NETWORK
INTERFACE

BASE Nx56/64

BASE DS-1

PBX

DTE CLOCK

T1 Transmit

T1 Receive

Summary of Contents for 1202155L1

Page 1: ...TDU 120e User Manual Part Number 1202156L2 1202155L2 September 2001 61202156L2 1C...

Page 2: ...a registered trademark of Microsoft Corp T Watch is a trademark of ADTRAN Inc OpenViewR 901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 Phone 256 963 8000 2001 ADTRAN Inc All rights re...

Page 3: ...dless type during an electrical storm There is a remote risk of shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord power supply...

Page 4: ...e changes in its facilities equipment oper ations or procedures that could affect the proper operation of your equip ment If they do you will be given advance notice so as to give you an opportunity t...

Page 5: ...d transmitted on the network The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog...

Page 6: ...stment of the digital CPE with respect to encoded analog content and billing protection information continuously complies with Part 68 of the FCC rules and Regulations The digital CPE does not transmi...

Page 7: ...d in accordance with _______________ circle one above I agree to provide ____________________ telco s name with proper documenta tion to demonstrate compliance with the information in the preceding pa...

Page 8: ...n which case the user will be required to correct the interference at his own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits Canadian Emissions Requir...

Page 9: ...s Repairs to certified equipment should be made by an authorized Canadian main tenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment ma...

Page 10: ...becomes null and void if Customer modifies or alters the equipment in any way other than as specifically authorized by ADTRAN EXCEPT FOR THE LIMITED WARRANTY DESCRIBED ABOVE THE FOREGO ING CONSTITUTES...

Page 11: ...low Presales Inquiries and Applications Support Please contact your local distributor ADTRAN Applications Engineering or ADTRAN Sales Post Sale Support Please contact your local distributor first If y...

Page 12: ...Service 901 Explorer Blvd Huntsville Alabama 35806 RMA _____________ Training The Enterprise Network EN Technical Training offers training on our most popu lar products These courses include overview...

Page 13: ...rface 1 4 Voice interface 1 4 OCU DP 1 4 DSU DP 1 4 Dial backup 1 4 U BR1TE 1 4 Option Module Architecture 1 5 TDU 120e Configuration Applications 1 6 Router PBX Video Conferencing Application 1 6 Cha...

Page 14: ...Out 2 10 Normal Power Up Procedure 2 11 Chapter 3 Operation 3 1 Menu Operation 3 1 Sample Terminal Screen with TDU 120e Menu 3 2 General Menu Traversal 3 2 Select and Activate a Menu Item 3 2 Edit the...

Page 15: ...over an EIA 232 Connection 3 12 SNMP 3 12 Chapter 4 Status Menu 4 1 Status 4 1 Network NI Performance Reports 4 2 Network Interface NI Errors 4 3 CRC 4 3 BPV 4 3 XSO 4 3 FER 4 3 Active Alarms 4 3 Vie...

Page 16: ...Det 5 13 Bit Stuffing 5 13 TR 08 Options 5 13 Unit Menu 5 14 Control Port Rate 5 14 Traps 5 14 Access 5 14 Init Modem 5 14 Control Port 5 15 IP Address 5 15 Subnet Address 5 15 Default Router 5 15 SLI...

Page 17: ...DS 1 0 2 Menu Items 5 28 Format 5 28 Code 5 28 Yellow Alarm 5 28 Line Length ft 5 28 Inband Loopback 5 28 Robbed Bit Signaling 5 29 RBS Start 5 29 RBS End 5 29 Chapter 6 Utility Menu 6 1 Util 6 1 Time...

Page 18: ...7 5 QRSS All DS0s 7 5 QRSS TST DS0s 7 6 None 7 6 Instructions for Generating a QRSS Test Pattern 7 6 Pattern Result 7 6 ES 7 6 BES 7 6 SES 7 7 SYNC 7 7 How to Run an End to End Test on Fractional DS0...

Page 19: ...5 System Contact 8 5 System Location 8 5 Auth Fail Traps Sent 8 5 Poll Link Status Traps Sent 8 5 Ping IP Host 8 6 Telnet Terminal Timeout 8 6 Telnet Terminal Password 8 6 Exit 8 6 Flash Download 8 6...

Page 20: ...Table of Contents xx TDU 120e User Manual 61202156L2 1...

Page 21: ...Layout 3 7 Figure 4 1 Status Menu Tree 4 1 Figure 4 2 Network Interface Performance Report 4 2 Figure 5 1 TDU 120e Config Menu Tree 5 2 Figure 5 2 Network NI Menu Tree 5 3 Figure 5 3 Unit Menu Tree 5...

Page 22: ...List of Figures xxii TDU 120e User Manual 61202156L2 1...

Page 23: ...inout of the Male 15 Pin D Connector B 2 Table B 3 Control In Chain In Pinout B 2 Table B 4 Chain Out Pinout B 3 Table B 5 Craft Port Pinout B 4 Table B 6 V 35 Pinout for Nx56 64 DTE B 5 Table B 7 Bas...

Page 24: ...List of Tables xxiv TDU 120e User Manual 612022156L2 1...

Page 25: ...local area network LAN bridges and routers computers CAD systems teleconferencing equipment PBXs Through the use of multiple data ports the TDU 120e can simultaneously connect one or more of these de...

Page 26: ...es provides a path for growth to accommo date future requirements The TDU 120e offers a wide variety of network manage ment options The 10BaseT and control ports are compat ible with both SNMP and T W...

Page 27: ...ed to the control port on the rear of the unit or the craft port on front of the unit Two programmable configuration maps that define the bandwidth allocation between data ports Data drop and insert a...

Page 28: ...This module includes a long haul DS 1 interface It can also be used as a second DS 1 interface to provide an up to 3 MB aggregate throughput Nx56 64 serial interface Provides a V 35 serial interface...

Page 29: ...for growth to accommodate an other application See Figure 1 1 Figure 1 1 TDU 120e Option Modules DSX 1 Module Plug on V 35 Plug on OCU DP Plug on Dual Voice OCU DP Module V 35 Module D I Module DUAL V...

Page 30: ...se DS 1 interface An OCU DP module and OCU DP plug on board provide two switched 56 circuits for video conferencing The 10BaseT port allows SNMP network management over the LAN See Figure 1 2 Figure 1...

Page 31: ...front section of this manual for contact informa tion If possible keep the original shipping container for use in shipping the TDU 120e back for repair or for verifi cation of damage during shipment A...

Page 32: ...t features POWER CONNECTION AC Powered Units Each TDU 120e AC unit is equipped with a captive eight foot power cord terminated by a three prong plug which connects to a grounded power receptacle DC Po...

Page 33: ...o be connect ed to ground at the service equipment The attachment plug receptacles in the vicinity of the product or system are all to be of a grounding type The equipment grounding conductors serving...

Page 34: ...m or to any grounded item that is permanently and reli ably connected to the electrical service equipment ground The supplemental grounding conductor shall be con nected to the equipment using a numbe...

Page 35: ...2156L2 1 TDU 120e User Manual 2 5 IDENTIFICATION OF REAR PANEL LAYOUT Figure 2 1 shows the configuration of the rear panel of the TDU 120e AC powered and DC powered units Figure 2 1 TDU 120e Rear Pane...

Page 36: ...ork Interface NI port provides the connection to the T1 This port complies with the applicable ANSI and AT T standards For more information see Appendix B Nx56 64 Serial Interface The Nx56 64 provides...

Page 37: ...craft port and the control port in put may be connected simultaneously but only one port may be active at a time For more information see Appendix B Control Out Port The chain port output provides an...

Page 38: ...st Now Testing and Memory Test Now Testing The test LEDs are illuminated The self test is completed All LEDs go back to their normal state The terminal momentarily displays System Self test Tests pass...

Page 39: ...respond to remote control controlled by a device other than the front panel or ter minal If no Unit ID is recorded it is not possible to oper ate from any remote control device including the local PC...

Page 40: ...her to form a chain Figure 2 3 provides an example of a chain in arrangement with a PC or a modem The first TDU 120e in the chain receives controlling input from the PC or modem Figure 2 3 Example of...

Page 41: ...Unit ID and the Control Port settings are stored in a nonvolatile memory This ensures they are operable for subsequent power up sequences NORMAL POWER UP PROCEDURE After the unit has been put into op...

Page 42: ...Chapter 2 Installation 2 12 TDU 120e User Manual 61202156L2 1...

Page 43: ...rd is ADTRAN You can change this password using the MANAGEMENT sub menu For detailed information on this method of control see the Telnet Terminal Main Menu on page 3 5 You can also connect to the TDU...

Page 44: ...DU 120e uses a multilevel menu structure contain ing both menu items and data fields All menu operations and data are displayed on the terminal Select and Activate a Menu Item To choose a menu item pl...

Page 45: ...n the number next to the activated selection 2 Press Enter The STATUS submenus will display 3 Use the arrow keys to view submenu items 4 Choose an item on the submenu such as ACTIVE ALARMS The cursor...

Page 46: ...g on interface is installed in the option slot it would be designated as DSX 1 Passthru 1 1 Where slot 1 and port 1 The DSX 1 is located in the option slot and is the first port in that slot Nx56 64 1...

Page 47: ...in Menu The TDU 120e uses a multilevel menu structure contain ing both menu items and data fields All menu operations and data display in the terminal window The first menu displayed after the Telnet...

Page 48: ...tion including all network interface parameters the allo cation of the DS0s and the port parameters For detailed information on configuration options see Chapter 5 Con figuration Menu Util Utilities...

Page 49: ...operation and con trols the configuration of the unit The TDU 120e front panel is shown in Figure 3 4 Figure 3 4 TDU 120e Front Panel Layout The following pages contain descriptions of each part of t...

Page 50: ...re energize Remote LED The remote LED yellow indicates a management session terminal mode or Telnet is active The LED does not ac tivate turn on during SNMP sessions Craft Port The Craft Port is used...

Page 51: ...s a self test or a test loopback When lighted this LED also indicates that normal data flow is not occurring on the network interface Error Red An error has occurred such as a BPV OOF or CRC Alarm Red...

Page 52: ...cludes a self test or a test loopback When lighted also indicates that normal data flow is not occurring in at least one of the module ports Alarm Red An alarm condition has been detected Any alarm co...

Page 53: ...ing into a remote TDU 120e location to configure the unit or read the status or performance of the unit Receives traps from any TSU product Records and creates display performance data over a 30 day p...

Page 54: ...1 Set the Unit ID and set a passcode See page 6 3 2 Set the control port rate to the same setting as the PC Com port 3 Connect the PC Com port to the Chain In port on the TDU 120e using the DB 25 adap...

Page 55: ...e system to the pre vious menu level Press ESCAPE repeatedly to return the system to the main menu AS 1 NETWORK NI EF PERFORMANCE REPORTS ES SES 2 NETWORK NI ERRORS UAS NETWORK NI 1 STATUS RED ALARM 3...

Page 56: ...is data accumulated over the last 15 minutes and over the last 24 hours Figure 4 2 Network Interface Performance Report Where Means AS Percentage of available seconds EF Percentage of error free seco...

Page 57: ...lid only in ESF mode BPV Bipolar violations XSO Excess zeros FER Framing errors Active Alarms This menu item displays a list of current alarms reported by either the base controller or any of the port...

Page 58: ...of test activation and deactivation To clear the VIEW HISTORY display press C Port Status PORT STATUS displays the signals monitored on the data ports For example the Nx DBU interface monitors the RT...

Page 59: ...toward the DTE XSO Excess zeros from the DTE LCK Lock status of the phase locked loop DTE Status An asterisk indicates an active status of the following lines RTS Request to send from DTE CTS Clear t...

Page 60: ...from the DCE DCD Data carrier detect from the DCE RI Ring indicate from the DCE DBU Control An asterisk indicates an active status on the following lines RTS Request to send the DCE CTS Clear to send...

Page 61: ...risk displays under the SLIP if the DS 1 detects frame slips This is caused by multiple clock sources in the application FER An asterisk displays under the FER if the DS 1 detects frame bit synchroniz...

Page 62: ...20e chassis Ethernet Status TX Indicates that data is being transmitted from the 10BaseT port RX Indicates that data is being received by the 10BaseT port LNK Indicates the current status of the 10Bas...

Page 63: ...ion including all network interface parame ters the allocation of the DS0s and the port parameters See the TDU 120e Config Menu Tree on page 5 2 Menu flow is depicted from left to right At every level...

Page 64: ...3 IDLE 15 IDLE 4 IDLE 16 IDLE CONFIG 5 DS0 MAPS 5 IDLE 17 IDLE 6 IDLE 18 IDLE 7 IDLE 19 IDLE 8 IDLE 20 IDLE 9 IDLE 21 IDLE 10 IDLE 22 IDLE 11 IDLE 23 IDLE 12 IDLE 24 IDLE 1 COPY MAP A TO TEMP MAP 2 C...

Page 65: ...RMAL CSU 5 TIMING MODE INTERNAL NETWORK NI BASE DTE U BR1TE SLOT 1 BASE DS 1 SECONDARY SI 1 NETWORK 6 SET LINE BUILD OUT 0 0 7 5 15 0 22 5 AUTO ACCEPT ALL 7 REMOTE LOOPBACK DET REJECT ATT REJECT FT1 R...

Page 66: ...ABLE DISABLE 3 ACCESS DIRECT DIAL NONE 4 INIT MODEM CUSTOM HAYES MOTOROLA USR COURIER 2 UNIT 5 CONTROL PORT NORMAL 6 IP ADDRESS 000 000 000 000 7 SUBNET ADDRESS 000 000 000 000 8 DEFAULT ROUTER 000 00...

Page 67: ...h may be necessary for a secondary interface DS 1 Passthru etc Network NI Menu Items FORMAT Sets the frame format for the NI Choices D4 ESF SLC96 CODE Sets the line code for the NI Choices AMI and B8Z...

Page 68: ...from the NI Choices NETWORK BASE DTE BASE DS 1 NORMAL CSU only with DSX 1 option card U BR1TE only with U BR1TE option card INTERNAL and SECONDARY SI only with secondary port option card The selected...

Page 69: ...to the network where it is used to determine the transmission timing This option is also referred to as loop timed as the trans mission clock is derived from the received clock See Figure 5 4 Figure 5...

Page 70: ...e source of timing The TDU 120e uses the clock derived by the Base DS 1 interface for transmission timing See Figure 5 5 Figure 5 5 Base DS 1 Timed Clock Source INTERNAL OSCILLATOR SECONDARY INTERFACE...

Page 71: ...determine the trans mission timing This is typically used in applications where it is necessary to have the DTE as the primary clock source such as limited distance line drivers See Figure 5 6 Figure...

Page 72: ...d to use its own internal oscillator as the source of timing Applications include private line driver circuits where one end is set to network and the other to internal See Figure 5 7 Figure 5 7 Inter...

Page 73: ...interface is the source of timing The TDU 120e uses the clock derived by the secondary interface for transmission timing See Figure 5 8 Figure 5 8 Secondary Clock Source INTERNAL OSCILLATOR SECONDARY...

Page 74: ...source of all timings This timing option is the same as that typically used for CSUs It works equally well when the PBX is the source of timing In that configuration the network would not be provid in...

Page 75: ...1 403 Choices ACCEPT ALL REJECT ATT REJECT FT1 REJECT ATT FT1 REJECT ALL Bit Stuffing When enabled bit stuffing causes the TDU 120e to moni tor for ones 1s density violations and insert a one 1 when n...

Page 76: ...re Control Port Rate Sets the baud rate for communication with the PC or modem Choices 1200 2400 9600 19200 and 38400 KBPS Traps Enables or disables the transmission of trap messages Choices ENABLE an...

Page 77: ...tion IP address is the Network number It is used along with the TDU 120e IP address to determine which nodes must be reached through the default IP Gateway This value is set to 0 0 0 0 when the contro...

Page 78: ...of the Chain In Port A connection to ground indicates an alarm condition Choices ENABLE DISABLE Exit This selection will exit to the main configuration menu Map Exchange The MAP EXCHANGE menu enables...

Page 79: ...units the units automatically coordinate the automatic map switch by sending a map switch command from end to end over the FDL Only one end needs to be set to AUTO for this to work Map In Use This me...

Page 80: ...mp Map You can use the up and down arrows or number keys to move the cursor from one selection to another Press Enter to perform the action displayed to the right of the cursor TEMP MAP DS0 1 2 3 4 5...

Page 81: ...lize the TEMP Map to one of three configurations current Map A current Map B or all IDLE This step is optional 2 Edit the Temp Map so that it reflects the desired map configuration 3 Replace the curre...

Page 82: ...ap edit mode Upon entering this mode the cursor location moves to DS0 number one in the DS0 field of the Temp map 2 Move the cursor from one DS0 to another by using the up and down arrows Locate the D...

Page 83: ...s permits modification without disturbing the existing map When the modifications are com pleted the TEMP map is written to current MAP A B by selecting APPLY TEMP MAP TO MAP A B Create Temp Map Creat...

Page 84: ...A or MAP B Apply Temp to Map A B Writes the TEMP map into Map A B Apply is usually the last step in updating a map Port Configuration Port Config PORT CONFIGURATION selects and configures the parame t...

Page 85: ...ned to the Nx port Choices 56K OR 64K TX CLK CNTRL Controls the clock used by the TDU 120e to accept transmit TX data from the DTE The default is NORMAL If the interface cable is long causing a phase...

Page 86: ...s being transmitted toward the network If 0s are transmitted for more than 1 second the TDU 120e will force 1s Choices ON or OFF INBAND MODE The Nx56 64 port is capable of providing an inband communic...

Page 87: ...to backup mode only if a backup condition is detected This is ideal for controlling where calls originate Choices DISABLE ORIGINATE ANSWER Backup On Selects the conditions that cause the Nx DBU to ini...

Page 88: ...d to elapse between the net work going into alarm or no data transmissions and the backup beginning Choices 1 SEC 3 SEC 10 SEC 30 SEC 1 MIN 5 MIN 10 MIN Restore Delay Selects the time that elapses bet...

Page 89: ...will occur Choices 0 23 Test Day If weekly Backup test is selected selects which day to perform the test Choices MONDAY SUNDAY WKEND Lockout If no backup is desired from midnight Friday to mid night...

Page 90: ...face Choices AMI B8ZS Yellow Alarm YELLOW ALARM enables and disables the transmitting of yellow alarms Choices ENABLE DISABLE Line Length ft LINE LENGTH provides selection of the proper output level f...

Page 91: ...ommon channel signaling e g PRI For applications requiring robbed bit signalling as well as a messaging channel e g some proprietary PBX channels the ON ENA BLOCK selection is provided Choices OFF ON...

Page 92: ...Chapter 5 Configuration Menu 5 30 TDU 120e User Manual 61202156L2 1...

Page 93: ...lues or reinitiating the unit This menu also displays the unit software revision and the unit ID setting Figure 6 1 Utility Menu Tree TIME HH MM SS 1 TIME DATE DATE MM DD YY Returns all configurations...

Page 94: ...configured DS0 maps The CONTROL PORT RATE PASS CODE UNIT ID and IP PARAMETERS are not affected by the FACTORY RESTORE command A factory reinitialization can also be executed by holding the ACO button...

Page 95: ...see page xi of this manual No Passcode Desired At the NEW PASSCODE prompt in the Set Passcode menu press Enter without any numerical entry The sys tem nullifies the need to enter a password for subseq...

Page 96: ...o Unit ID recorded es tablishes the unit as not able to be operated by remote control Software Revision This menu provides access to the display of the current software revision level loaded into the...

Page 97: ...OCAL LOOPBCK NO LOOPBACK ANSI FDL LLB 3 REMOTE LOOPBCK ANSI FT1 LLB NO LOOPBACK ALL ONES 5 TEST 3 TEST PATTERN ALL ZEROS QRSS ALL DS0S QRSS PATTERN QRSS TST DS0S NONE ES 4 PATTERN RESULT BES SES 2 RUN...

Page 98: ...determine the type of loopback and the pattern to run Test results display in the LCD window Loopback Tests A number of different loopbacks can be invoked locally from the front panel by T Watch PRO c...

Page 99: ...dentical line code that was received including any bipolar violations or framing errors Payload Similar to line loopback except that the framing is extracted from the received data and then regenerate...

Page 100: ...pecified in ANSI T1 403 for payload and line loopback codes The following options are available ATT In Band LLB Activates the line loopback using inband code ANSI FDL PLB Initiates the transmission of...

Page 101: ...y used to simulate real data in T1 interfaces This pattern can be assigned to appear in all DS0s or only in TST DS0S When QRSS is set in all DS0s and one of the network loopbacks previ ously described...

Page 102: ...returning to this menu item does not interrupt the test Pressing 2 injects errors into the test pattern These errors are detected by the device performing the pattern check ES The number of seconds w...

Page 103: ...s for testing can be very useful particu larly in Fractional T1 applications How to Run an End to End Test on Fractional DS0s Step Action 1 Set the TST for Map B in the same DS0 as used by Map A to re...

Page 104: ...so run on various parts of the internal electronics These run during normal operation to confirm continued cor rect functioning This menu selection is used to execute a full internal self test The res...

Page 105: ...vation of loopbacks and the initiation of data test patterns Test results are dis played on the terminal screen Nx DBU 0 1 Menu Items Nx DBU 0 1 is the base Nx interface It offers the follow ing test...

Page 106: ...ck is disabled 511 RESULTS Displays the results of the 511 test indicated in the 511 option The results are in the form of the number of errored seconds The error count can be cleared by pressing C DB...

Page 107: ...DCD and RI to be monitored while the INTERFACE TST is on If the dial up network is correctly configured and dialed up there should be an asterisk over DCD DBU TST RESULT When an interface test is act...

Page 108: ...Chapter 7 Test Menu 7 12 TDU 120e User Manual 61202156L2 1...

Page 109: ...device may be another TSU TDU or any other ADTRAN prod uct that supports Telnet via its EIA 232 chain port After selecting this option the user may choose to connect to a device entered in the Unit A...

Page 110: ...alone Units accessed via T Watch PRO over TCP IP use the unit ID and passcode set by T Watch PRO running on the PC Figure 8 1 Unit Access Table It is not necessary to have an entry in this table for a...

Page 111: ...page 8 2 Traps are normally sent from the unit in alarm to the TDU 120e For units in the Unit Access Table that are not chained directly to the TDU 120e but are managed over Inband or the FDL traps ar...

Page 112: ...order for the NMS to have Read Write access to MIBS supported by the TDU 120e This value must be a text string that is 16 characters or less SNMP Trap Community This community name is used for all SN...

Page 113: ...r maintaining an SNMP managed node System Location A text string describing the physical location of an SNMP managed node for example SECOND FLOOR PBX ROOM Auth Fail Traps Sent When enabled the TDU 12...

Page 114: ...n of the password required for entry into a Telnet or terminal session The default value is ADTRAN Exit Returns to the TDU 120e Main menu Flash Download The TDU 120e uses flash memory that allows soft...

Page 115: ...e Select this item and press Enter to begin the flash upgrade using TFTP After the download is complete the TDU 120e will close the Telnet session to reprogram the software The Telnet session may be o...

Page 116: ...Chapter 8 Remote Management Menus 8 8 TDU 120e User Manual 61202156L2 1A...

Page 117: ...ry to manage the various vendor equipment from a single control console Thus the SNMP emerged as the standard for managing commercial TCP IP net works Basic Components of SNMP SNMP has three basic com...

Page 118: ...est to that network device The agent in that device interprets the incoming request performs the requested task and sends its response to the network manager The network manager collects all the data...

Page 119: ...ponse The response to a network manager GETREQUEST or GETNEXTREQUEST command Trap An unsolicited message issued by a network device to report an operational anomaly or an alarm condition to the networ...

Page 120: ...d a period and the Unit ID of the device to the Read and Read Write community names Example If Then The Read community name configured in the TDU 120e is public Specify public 3 as the community name...

Page 121: ...quired for Management Station trap con figuration are 1 loading the device specific MIBs and 2 loading or creating device specific Trap Definition Files The current product MIBs contain keywords embed...

Page 122: ...and RFC1406 MIB 2 Create device entries in the NMS database for all units that are to be managed through the TDU 120e The host unit should be configured as the Proxy agent for the external units The I...

Page 123: ...enterprise specific MIBs including ADTRAN Product MIB ADTRAN MIB ADTRAN DS1 extensions MIB ADS1 MIB and all TSU TDU Enterprise MIBs such as TDU 120e MIB The standard MIB files are usually included wit...

Page 124: ...Appendix A Understanding SNMP A 8 TDU 120e User Manual 61202156L2 1...

Page 125: ...B 1 for the pinout for the 8 pin modular connector and Table B 2 on page B 2 for the pi nout of the male 15 pin D connector Table B 1 Network Pinout of the 8 Pin Modular Connector Pin Name Descriptio...

Page 126: ...ata toward the Network 2 FG FRAME GROUND 3 T1 RXDATA TIP Receives data from the Network 4 FG FRAME GROUND 5 6 7 8 UNUSED 9 R TXDATA RING Sends data toward the Network 10 UNUSED 11 R1 RXDATA RING Recei...

Page 127: ...4 for the pinout for the chain out connector Table B 4 Chain Out Pinout Pin Name Description 1 GND Ground connected to unit chassis 2 UNUSED 3 TX DATA Data transmitted to chained units by the TDU 120e...

Page 128: ...ther TSU TDU family multiplexer or TSU 100 Chain In See Table B 5 for the pinout for the craft port connector Table B 5 Craft Port Pinout Pin Name Description 1 GND Ground connected to unit chassis 2...

Page 129: ...6 Clear to send CTS to DTE E 107 Data set ready DSR to DTE F 109 Received line signal detector DCD to DTE L J Local loopback LL N BB Remote loopback RL R 104 Received data RD A to DTE T 104 Received d...

Page 130: ...Table B 7 for the pinout of the 8 pin modular connec tor and Table B 8 on page B 7 for the pinout of the female 15 pin D Connector Table B 7 Base DS 1 Pinout of the 8 Pinout Modular Connector Pin Nam...

Page 131: ...male D Connector Pin Name Description 1 T RXDATA TIP Receives data from the DTE PBX 2 FG FRAME GROUND 3 T1 TXDATA TIP Sends data toward the DTE PBX 4 FG FRAME GROUND 5 6 7 8 NOT USED 9 R RXDATA RING R...

Page 132: ...ect the TDU 120e to an external alarm device See Table B 10 Connector Type 4 pin Eurostyle connector Power Table B 11 Power Connector DC powered units Table B 9 10BaseT Ethernet Connector Pin Name To...

Page 133: ...ace NI Red Alarm NI unable to frame align with incoming signal Yellow Alarm Remote alarm indication RAI being received from far end Blue Alarm Unframed all ones 1s AIS being received at NI Loss of Sig...

Page 134: ...Clock No external transmit clock at DTE only appears if EXT CLK is selected DS 1 PBX Interface The following messages indicate a condition on the Base DS 1 PBX interface Red Alarm Not able to frame d...

Page 135: ...Power On Unit powered on Self Test Internal self test performed Nx DBU Interface The following messages indicate the status of the Nx DBU card Loop Up Data is looped at both the network interface and...

Page 136: ...network interface DS 1 PBX Interface The following messages indicate the status of the DS 1 in terface Frame Slip Indicates a Frame Slip has occurred on the DS 1 interface This is present in Alarm His...

Page 137: ...75bps Line Code Bipolar RZ AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 Channelized multiple of 64 kbps Transmit Timing Network DTE U BR1TE Secondary NI Normal CSU or Internal Input Signal 0 to...

Page 138: ...V 35 Interface DCE Interface CCITT V 35 Synchronous Rates 56kbps 1 536Mbps in 56k or 64k increments Clock Options Normal Inverted and internal external Tests Local Loopback bilateral Remote Loopback V...

Page 139: ...des AMI B8ZS Framing ESF per ANSI T1 403 and AT T Pub TR 54016 D4 per AT T Pub 62411 Line Length Short haul mode 3 dBDsx to 655 feet in110 ft steps Line Build out Long haul mode 0 7 5 15 22 5 AUTO Tim...

Page 140: ...e Monitoring TR 54016 and T1 403 Approvals FCC Part 15 FCC Part 68 UL 1950 Management Interfaces Chain In Out Ports Craft Port Interface Devices PC Serial Port Modem or SLIP connection to router Inter...

Page 141: ...lded 8 pin modular Receiver accepts signal 300mV Protocols Network IP Transport TCP UDP Services SNMP TELNET ICMP ARP PING T Watch PRO Option Slot Interface Interface ADTRAN proprietary accepts standa...

Page 142: ...pecifications Input Power AC powered devices 90 120VAC 47 63 Hz DC powered devices or 48 VDC Fuse AC powered devices 0 6A 250V DC powered devices 1 5 A 250 V Operating Temperature 0 deg C to 45 deg C...

Page 143: ...1 interface alarm mes sage C 2 Blue Alarm network interface C 1 Board level tests self test 2 8 BPV network interface error 4 3 C Chain In Out Ports Craft Port D 4 Chain out connectors B 3 changing a...

Page 144: ...ng Instructions 2 3 H Host 1 Trap IP Address 8 4 Host 2 Trap IP Address 8 5 Host 3 Trap IP Address 8 5 Host 4 Trap IP Address 8 5 I Initialization for TDU 120e unit 2 9 Input Signal D 1 Installation h...

Page 145: ...C 3 Payload network interface loopback 7 3 Ping IP Host 8 6 PLL Alarm alarm message C 2 Poll Link Status Traps Sent 8 5 Port Loop Up status DS 1 PBX inter face C 4 Port Status LEDs 3 10 Port Status st...

Page 146: ...8 5 System Name for SNMP managed node ID 8 5 T T1 Line Rate D 1 T1 FT1 Interface D 1 TDU 120e Interfaces 2 6 TDU 120e features 1 3 Telnet Terminal Password 8 6 Telnet Terminal Timeout 8 6 Test Jacks D...

Reviews: