Chapter 5. Configuration Menu
61202156L2-1
TDU 120e User Manual
5-23
The
C
ONFIG
menus for options ports are described in sep-
arate sections of the manual supplied with the option
card.
Nx/DBU (0.1) Menu Items
The Nx/DBU port has two main menus:
N
X
56/64
CONFIG
-- Nx operation and
DBU
CONFIG
-- DBU
operation.
Nx56/64 Config
Under
N
X
56/64
CONFIG
, the menu items are:
DS0 RATE
This sets the base DS0 rate of the interface. The actual
data rate depends on the number of DS0s assigned to
the Nx port.
Choices:
56K
OR
64K
TX CLK CNTRL
Controls the clock used by the TDU 120e to accept
transmit (TX) data from the DTE. The default is
N
ORMAL
. If the interface cable is long, causing a
phase shift in the data, the clock can be selected as
I
NVERT
. This switches the phase of the clock which
should compensate for a long cable.
Choices:
N
ORMAL
,
I
NVERT
DATA
Used to control the inverting of the DTE data. This
inversion can be useful when operating with an
HDLC protocol. Often used as a means to ensure 1s
density.
Choices:
N
ORMAL
or
I
NVERT
If
I
NVERT
is selected, zero (0) inhibit should also be selected to prevent an
open DTE input from placing zeros on the network.
Summary of Contents for 1202155L1
Page 1: ...TDU 120e User Manual Part Number 1202156L2 1202155L2 September 2001 61202156L2 1C...
Page 20: ...Table of Contents xx TDU 120e User Manual 61202156L2 1...
Page 22: ...List of Figures xxii TDU 120e User Manual 61202156L2 1...
Page 24: ...List of Tables xxiv TDU 120e User Manual 612022156L2 1...
Page 42: ...Chapter 2 Installation 2 12 TDU 120e User Manual 61202156L2 1...
Page 92: ...Chapter 5 Configuration Menu 5 30 TDU 120e User Manual 61202156L2 1...
Page 108: ...Chapter 7 Test Menu 7 12 TDU 120e User Manual 61202156L2 1...
Page 116: ...Chapter 8 Remote Management Menus 8 8 TDU 120e User Manual 61202156L2 1A...
Page 124: ...Appendix A Understanding SNMP A 8 TDU 120e User Manual 61202156L2 1...