Installation and User Manual
ADPRO FastTrace by Xtralis
66
Doc 11168_12
Figure 66: Advanced Serial Communications
Local IP Address
Factory Default:
192.168.254.1
Sets the
Local IP Address
assigned to FastTrace’s COMMS port. This address is used by the
PPP messaging software and is
NOT
the same as the Ethernet Properties setting or of
any
other device on the network
.
When multiple FastTrace units are to be accessed from a single VideoCentral system, each
FastTrace unit MUST have a unique Local IP Address (ie. do not leave at the factory default
address) for each serial and ethernet connection.
For more information, please refer to:
Tech Tip 10470_00 - Unique IP Address Requirements, available on the website:
www.xtralis.com/adpro
.
Caution:
Contact Xtralis technical support for advice before entering data into:
Enable PAP
,
PPP Username
or
PPP Password
.
Enable PAP
Factory Default:
No
Set this checkbox to enable Password Authentication Protocol. PAP will authenticate the remote
system during the PPP negotiations. The valid username and password are defined by the fields
of PPP Username and PPP Password.
PPP Username
Option:
20 characters maximum.
The
Username
(or Site Name) that will be provided by PPP when negotiating a serial IP
connection. It is only required when PAP is enabled.
Note:
The PPP Username is a function of the modem or TA and will also need to be set in
the device.
Summary of Contents for ADPRO FastTrace
Page 1: ...ADPRO FastTrace by Xtralis Installation and User Manual March 16 2010 Part 201172 12 ...
Page 2: ......
Page 134: ...Installation and User Manual ADPRO FastTrace by Xtralis 122 Doc 11168_12 ...
Page 136: ...Installation and User Manual ADPRO FastTrace by Xtralis 124 Doc 11168_12 ...
Page 146: ...Installation and User Manual ADPRO FastTrace by Xtralis 134 Doc 11168_12 ...