background image

34

Jumpers and Connectors

DE Connectors (44-pin, CN2)

Signal

Pin

Pin

Signal

RESET-

1

2

Ground

DD7

3

4

DD8

DD6

5

6

DD9

DD5

7

8

DD10

DD4

9

10

DD11

DD3

11

12

DD12

DD2

13

14

DD13

DD1

15

16

DD14

DD0

17

18

DD15

Ground

19

20

(keypin)

DMARQ

21

22

Ground

DIOW-

23

24

Ground

DIOR-

25

26

Ground

IORDY

27

28

CSEL

DMACK-

29

30

Ground

INTRQ

31

32

reserved

DA1

33

34

PDIAG-

DA0

35

36

DA2

CS0-

37

38

CS1-

DASP-

39

40

Ground

+5V

41

42

+5V

Ground

43

44

TYPE-

Table  2-7: Secondary IDE channel (CN2) on cPCI-6760D front board

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for NuIPC cPCI-6760D Series

Page 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In...

Page 2: ...cember 21 2006 Part No 50 15006 101 NuIPC cPCI 6760D series 6U CompactPCI Highly Integrated Single Slot Dual Bridge Low Power Pentium III CPU Module and Rear I O Transition Module Artisan Technology G...

Page 3: ...umentation even if advised of the possibility of such damages This document contains proprietary information protected by copy right All rights are reserved No part of this manual may be repro duced b...

Page 4: ...2 82265717 Address 9F No 166 Jian Yi Road Chungho City Taipei 235 Taiwan Please email or FAX this completed service form for prompt and satisfactory service Company Information Company Organization Co...

Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 6: ...outline drawing 24 2 Jumpers and Connectors 25 Jumpers and connectors map of cPCI 6760D series front board 26 Jumpers and connectors map of cPCI R6760D board 28 Jumpers and connectors map of cPCI R67...

Page 7: ...ard Connector CN13 51 Mouse Connector CN12 51 Ethernet Connectors CN7 CN8 51 Serial Port COM2 Connector CN10 52 Serial Port COM1 Pin Headers CN5 52 Parallel Port Connector CN11 53 VGA Connector CN6 53...

Page 8: ...CF Outline Jumper and Connectors 77 DB 6760CF Installation for cPCI 6760D and CF card notice 78 Removing DB 6760CF from cPCI 6760D 78 3 4 HDD Installation 79 HDD FFD Installation for cPCI 6760D 79 Rem...

Page 9: ...Installation on Windows NT 99 5 Watchdog and Utilities 101 5 1 Watchdog Timer Configuration 101 WDT Programming 101 How to Test the WDT 102 5 2 Hardware Doctor Utility 103 5 3 Intel Preboot Execution...

Page 10: ...0D front board 34 Table 2 8 Micro Switch Connector CN8 on cPCI 6760D 35 Table 2 9 CompactPCI J1 pin assignments 36 Table 2 10 CompactPCI J2 Pin Assignments 37 Table 2 11 CompactPCI J3 pin assignments...

Page 11: ...tPCI J5 pin assignments on cPCI R6760D rear board 57 Table 2 37 Amber LED indication in LAN port on cPCI R6760D rear board 58 Table 2 38 Green LED indication in LAN port on cPCI R6760D rear board 58 T...

Page 12: ...2 54 CompactPCI rJ3 pin assignments on cPCI R6760S rear board 70 Table 2 55 CompactPCI rJ4 pin assignments on cPCI R6760S rear board 71 Table 2 56 CompactPCI rJ5 pin assignments on cPCI R6760S rear b...

Page 13: ...ront View 26 Figure 2 2 Bottom and Front Panel View 27 Figure 2 3 Jumpers and connectors map of cPCI R6760D board 28 Figure 2 4 Jumpers and connectors map of cPCI R6760S series board 29 Figure 2 5 IDE...

Page 14: ...s not necessary to use the rear board if the application requires only front panel I O wiring or special backplane wiring The front board the CPU module and the rear board the rear I O transition modu...

Page 15: ...nfiguration of 2 5 ATA HDD or by OEM project request X Y cable for PS 2 keyboard and mouse connection P N 30 01016 000 X This User s Manual X ADLINK CD Rear Board The rear board is a rear I O transiti...

Page 16: ...es the Intel 440BX AGPset chipset which supports processor front side bus FSB running at 100MHz and PC 100 SDRAM up to 512MB with optional ECC capacity The highly integrated design allows the cPCI 676...

Page 17: ...RTM provides the extra functionality expansion for cPCI 6760D It provides the I O access of Ultra 160 SCSI four Ethernet ports keyboard mouse COM2 RS 232 422 485 and one USB on rear panel The module...

Page 18: ...SB 2 2 Ethernet Port 2 Ports Intel 82599 Fast Ethernet Controller 2 Ports Intel 82599 Fast Ethernet Controller EIDE 2 UDMA 33 channels 2 UDMA 33 channels FDD I F Yes Yes Flash Stor age Removable Compa...

Page 19: ...rs on board and DB 9 on faceplate RS 232 422 485 Parallel Port DB 25 on faceplate Reserved pin headers on board USB One connector on face plate One connector on faceplate EIDE Two 40 pin interfaces on...

Page 20: ...ndary bridge on J4 and J5 Using cPCI R6760S with a 14 slot support backplane may cause conflict between the add on card s PCI bus mastering devices and the onboard PCI bus mastering devices such as Ul...

Page 21: ...actPCI bus peripheral slots not available on cPCI R6760S X Onboard high performance AGP 2x VGA display output by SMI SM721 controller X Supports up to dual 10 100Mb Ethernet ports up to four 10 100Mb...

Page 22: ...ache 700MHz speed and 100MHz FSB for cPCI 6760D P7 X Intel BGA2 Mobile Pentium III with 256KB on die L2 cache 850MHz speed 100MHz FSB for cPCI 6760D P8 X Intel BGA2 Low Voltage Celeron with 128KB on d...

Page 23: ...6105R cBP 6515R cBP 6402 and cBP 6309 backplanes X One 44 pin secondary EIDE connector on the front CPU module which can support an onboard 2 5 notebook size HDD or Flash2000TM flash disk X One Compa...

Page 24: ...ransition module USB Interface X Supports up to two USB ports one port on front CPU module another port on rear I O transition module X USB Specification Rev 1 1 compliant X Individual over current pr...

Page 25: ...e X AGP 2x ACPI VESA DPMS and VESA DDC 2b compliant X Supports up to 1280x1024 VGA display resolution with 24 bit true color non interlaced X Supports up to 1600x1200 VGA display resolution with 16 bi...

Page 26: ...Balancing ALB Fast Ethernet Channel FEC and Link Aggregation OS Compatibility X MS DOS 6 2 Windows 95 98 ME Windows NT 4 0 Windows 2000 Red Hat Linux 7 2 and VxWorks Flash Disk Support X Supports Com...

Page 27: ...le limit switch for soft power off signal triggering X Flush tact switch for system reset Environment X Operating temperature 0 to 60 C X Storage temperature 20 to 80 C X Humidity 5 to 95 non condense...

Page 28: ...was tested when the HDD is cabled outside the testing chamber along with the Mobile Pentium III 850MHz CPU 3 The vibration limitation of operation is caused by the 2 5 ATA HDD Should customers wish to...

Page 29: ...ort for selectable RS 232 422 485 on rear faceplate X Reserved one 10 pin interface for COM1 RS 232 onboard for customized application X Separate PS 2 type keyboard and mouse connectors on rear facepl...

Page 30: ...liant X PICMG 2 7 CompactPCI R1 0 secondary CompactPCI bus pin definitions compliant X IEEE 1101 11 rear transition module mechanism compliant Form Factor X Standard 6U CompactPCI board size 233 35mm...

Page 31: ...and reserved one 10 pin interface onboard for selectable RS 232 422 485 COM2 port X Separate PS 2 type keyboard and mouse connectors on rear faceplate USB Interface X One USB type A connector on rear...

Page 32: ...10 100Mb indicator amber LED for each port CAUTION IDE2 COM1 Keyboard Mouse VGA and dual LAN ports support wiring by either front or rear I O Connect the device either by front or rear I O for one I O...

Page 33: ...B A Y USB B Y J5 PC Beeper Buzzer 10 100Mb Ethernet Port 1 Y RJ 45 Y J3 RJ 45 10 100Mb Ethernet Port 2 Y RJ 45 Y J3 RJ 45 VGA Y DB 15 Y J5 DB 15 LEDs Y Y Ethernet Reset button Y CompactFlash via daugh...

Page 34: ...EIDE Y J3 40 pin Ultra DMA 33 Secondary EIDE Y 44 pin Y J5 40 pin USB A Y USB B Y J5 PC Beeper Buzzer 10 100Mb Ethernet Port 1 Y RJ 45 Y J3 RJ 45 10 100Mb Ethernet Port 2 Y RJ 45 Y J3 RJ 45 10 100Mb...

Page 35: ...on module Please refer to Chapter 2 for Ethernet front I O or rear I O connecting selection switch setting and Chapter 3 for the rear I O transition module Note Ethernet ports 3 4 and Ultra 160 SCSI a...

Page 36: ...M e m o r y B U S 1 0 0 M H Z S O D IM M H o s t B u s 1 0 0 M H Z L o w P o w e r M o b ile C P U U S B P IIX 4 E I S A B u s 1 6 M H Z B IO S H W M W 8 3 7 8 2 D S u p e r I O P R T K B M S C O M F...

Page 37: ...eries front board A G P s e t 8 2 4 4 3 B X t in e l 8 2 3 7 1 E B P C I s e t t ni l e i 8 2 5 5 9 i 8 2 5 5 9 B A T T E R Y C O M 1 V G A P M C K B M S U S B L A N 1 L A N 2 H D W D P W H S R S T Ar...

Page 38: ...dicators on the cPCI 6760D Topics covered include X Jumpers Connectors and LED indicators on the cPCI 6760D X Jumpers Connectors and LED indicators on the cPCI R6760D X Jumpers Connectors and LED indi...

Page 39: ...u p e r I O S o u th B rid g e P IIX 4 E 8 2 3 7 1 E B J 5 J 4 J 3 J 1 J 2 4 4 p in S e c o n d a ry E ID E C N 2 1 4 4 P in S O D IM M 1 4 4 P in S O D IM M P M C C o n n e c to r S M I V G A S M 7 2...

Page 40: ...H S R S T S 1 S 2 S 3 S 4 P 2 P B rid g e P C I2 0 5 0 P 2 P B rid g e P C I2 0 5 0 R e s e rv e d fo r E C C R A M C O M 1 C N 1 V G A C N 3 P M C S lo t O p e n in g K e y b o a rd a n d M o u s e C...

Page 41: ...pers and connectors map of cPCI R6760D board rJ3 rJ5 FDD CN3 IDE1 CN2 IDE2 CN4 COM 1 CN5 Speaker CN14 JP2 JP3 JP4 JP5 Buzzer LPT LAN2 LAN1 KB M S USB COM 2 VGA CN11 CN8 CN7 CN12 CN13 CN9 CN10 CN6 Arti...

Page 42: ...I rJ4 rJ5 C N 2 ID E2 C N 1 LPT Intel 82559 Intel 82559 B uzzer JP4 JP5 JP6 JP7 C N 18 U SB C N 19 C O M 2 C N 21 M S C N 22 K B C N 14 LA N 1 C N 15 LA N 2 C N 16 LA N 3 C N 17 LA N 4 C N 20 SC SI C...

Page 43: ...such as keyboard mouse VGA COM port Ethernet etc Note There are no jumpers for front side bus FSB and CPU speed selection cPCI 6760D is equipped with a BGA2 pre soldered CPU that is mounted during SMT...

Page 44: ...tion 1 KBDATA Keyboard Data 2 MSDATA Mouse Data 3 GND Ground 4 5V Power 5 KBCLK Keyboard Clock 6 MSCLK Mouse Clock Table 2 2 Keyboard Mouse Combo Connector CN4 on cPCI 6760D front board Note A Y cable...

Page 45: ...6760D front board Pin Signal Name 1 DCD Data carrier detect 2 RXD Receive data 3 TXD Transmit data 4 DTR Data terminal ready 5 GND Ground 6 DSR Data set ready 7 RTS Request to send 8 CTS Clear to sen...

Page 46: ...me Pin Pin Signal Name Red 1 2 Green Blue 3 4 N C GND 5 6 GND GND 7 8 GND 5V 9 10 GND N C 11 12 N C HSYNC 13 14 VSYNC NC 15 Table 2 5 VGA Connector CN3 on cPCI 6760D front board Pin Signal Name 1 Vcc...

Page 47: ...17 18 DD15 Ground 19 20 keypin DMARQ 21 22 Ground DIOW 23 24 Ground DIOR 25 26 Ground IORDY 27 28 CSEL DMACK 29 30 Ground INTRQ 31 32 reserved DA1 33 34 PDIAG DA0 35 36 DA2 CS0 37 38 CS1 DASP 39 40 G...

Page 48: ...35 Micro Switch Connector CN8 Pin Signal Name 1 Power Button 2 5V 3 GND Table 2 8 Micro Switch Connector CN8 on cPCI 6760D P in 1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SO...

Page 49: ...STOP S1LOCK GND 15 GND 3 3V S1FRAME S1IRDY BDSEL 7 S1TRDY GND 12 14 Key 11 GND S1AD 18 S1AD 17 S1AD 16 GND S1C BE 2 GND 10 GND S1AD 21 GND 3 3V S1AD 20 S1AD 19 GND 9 GND S1C BE 3 IDSEL 8 S1AD 23 GND S...

Page 50: ...ND 12 GND Reserved Reserved Reserved GND Reserved GND 11 GND Reserved GND V I O 1 Reserved Reserved GND 10 GND Reserved Reserved Reserved GND Reserved GND 9 GND Reserved GND V I O 1 Reserved Reserved...

Page 51: ...DEX WDATA GND 11 GND DS1 DSKCHG MTR1 DRVDEN0 RDATA GND 10 GND WRTPRT HDSEL FDIR TRACK0 STEP GND 9 GND WGATE ERRORP AUTOFD PBUSY Reserved GND 8 GND PE SLCTIN 5V 4 PSTROB Reserved GND 7 GND PPD7 PPD6 PP...

Page 52: ...ed S2STOP S2LOCK GND 15 GND 3 3V 4 S2FRAME S2IRDY GND S2TRDY GND 12 14 KEY 11 GND S2AD 18 S2AD 17 S2AD 16 GND S2C BE 2 GND 10 GND S2AD 21 GND 3 3V 4 S2AD 20 S2AD 19 GND 9 GND S2C BE 3 GND S2AD 23 GND...

Page 53: ...GND Reserved SDIOW SDIOR GND 12 GND SPDIAG SDCS16 SDDACK GND SDIRQ15 GND 11 GND SDA0 GND Reserved SDA2 SDA1 GND 10 GND GREEN SDACT SDCS3 GND SDCS1 GND 9 GND HSYNC GND Reserved RED BLUE GND 8 GND DDCC...

Page 54: ...e default BIOS setting is set to disabled and the factory default hardware configuration is IRQ 9 To support PICMG 2 1 hot swap for peripheral boards the backplane should bus all peripheral slots ENUM...

Page 55: ...25 26 C BEJ 3 AD 22 27 28 AD 21 AD 19 29 30 5V PMCVIO 4 31 32 AD 17 FRAME 33 34 GND GND 35 36 IRDY DEVSEL 37 38 5V GND 39 40 LCOK RESERVED 1 41 42 RESERVED 1 PAR 43 44 GND PMCVIO 4 45 46 AD 15 AD 12 4...

Page 56: ...IDSEL 25 26 AD 23 3 3V 27 28 AD 20 AD 18 29 30 GND AD 16 31 32 C BEJ 2 GND 33 34 RESERVED 1 TRDY 35 36 3 3V GND 37 38 STOP PERR 39 40 GND 3 3V 41 42 SERR C BEJ1 43 44 GND AD 14 45 46 AD13 M66EN 47 48...

Page 57: ...fault factory setting is tight to 5V by 0 ohm resistors R46 and R48 When the R46 and R48 are removed and R47 and R49 are installed with 0 ohm resistors the PMC VIO is 3 3V 5 M66EN is tied to ground Th...

Page 58: ...DE Activity LED Indication Green LED Link Activity Status Description OFF No link ON Connecting Blinking Active Data transferring Table 2 17 Green LED indication in LAN port Artisan Technology Group Q...

Page 59: ...cription OFF System is not power on or power failed ON System is power on Table 2 19 Power LED indication Amber LED Description OFF WDT is not enabled Blinking WDT is enabled Table 2 20 WDT LED indica...

Page 60: ...designed such that customers can choose either front or rear I O for the most suitable wiring by setting the mini switch There are four mini switches located on the bottom side solder side of cPCI 67...

Page 61: ...OFF S3 4 ON S4 4 OFF Rear I O S3 1 OFF S4 1 ON S3 2 OFF S4 2 ON S3 3 OFF S4 3 ON S3 4 OFF S4 4 ON Table 2 23 LAN2 Connecting Selection CAUTION Do not set both S1 and S2 ON or set both S3 and S4 ON si...

Page 62: ...oard allow users to connect devices such as keyboard mouse VGA COM port Ethernet USB and printer ports The LED indicators on the cPCI R6760D rear board displays the system s status CAUTION Some I O po...

Page 63: ...3 4 1 3 2 4 1 3 2 4 RS 485 3 5 4 6 1 2 1 3 2 4 1 3 2 4 RS 485 1 3 2 4 1 2 1 3 2 4 1 3 2 4 Note RS 485 is an advanced feature that enables the hardware auto redirection function on the RS 485 net work...

Page 64: ...Keyboard Connector CN13 on cPCI R6760D rear board Pin Signal Function 1 MSDATA Mouse Data 2 NC No Connect 3 GND Ground 4 5V Power 5 MSCLK Mouse Clock 6 NC No Connect Table 2 26 Mouse Connector CN12 o...

Page 65: ...8 CTS Clear to send NC NC 9 RI Ring indicator NC NC Table 2 28 Serial Ports COM2 CN10 on cPCI R6760D rear board faceplate Pin Signal Name 1 DCD Data carrier detect 3 RXD Receive data 5 TXD Transmit d...

Page 66: ...5 7 20 Ground PD6 parallel data 6 8 21 Ground PD7 parallel data 7 9 22 Ground ACK acknowledge 10 23 Ground Busy 11 24 Ground Paper empty 12 25 Ground Select 13 N A N A Table 2 30 Parallel Ports LPT1 C...

Page 67: ...0 DD4 9 10 DD11 DD3 11 12 DD12 DD2 13 14 DD13 DD1 15 16 DD14 DD0 17 18 DD15 Ground 19 20 5V for DOM DMARQ 21 22 Ground DIOW 23 24 Ground DIOR 25 26 Ground IORDY 27 28 CSEL DMACK 29 30 Ground INTRQ 31...

Page 68: ...round 11 12 DS1 Ground 13 14 DS0 Ground 15 16 MTR1 Ground 17 18 FDIR Ground 19 20 STEP Ground 21 22 WDATA Ground 23 24 WGATE Ground 25 26 TRACK0 Ground 27 28 WPT Ground 29 30 RDATA Ground 31 32 HDSEL...

Page 69: ...D3 PDD2 PDD1 PDD0 PDIOR GND 12 GND DS0 DRVDEN1 MTR0 INDEX WDATA GND 11 GND DS1 DSKCHG MTR1 DRVDEN0 RDATA GND 10 GND WRTPRT HDSEL FDIR TRACK0 STEP GND 9 GND WGATE ERRORP AUTOFD PBUSY Reserved GND 8 GND...

Page 70: ...SDIOR GND 12 GND SPDIAG SDCS16 SDDACK GND SDIRQ15 GND 11 GND SDA0 GND V I O 1 SDA2 SDA1 GND 10 GND GREEN SDACT SDCS3 GND SDCS1 GND 9 GND HSYNC GND V I O 1 RED BLUE GND 8 GND DDCCLK DDCDAT SPDLED2 GND...

Page 71: ...mber LED 10 100Mbps Status Description OFF 10Mbps transfer rate ON 100Mbps transfer rate Table 2 37 Amber LED indication in LAN port on cPCI R6760D rear board Green LED Link Activity Status Descriptio...

Page 72: ...ort Ethernet USB and SCSI The LED indicators on the cPCI R6760S rear board displays the system s status The following information lists the jumpers connectors and LEDs on cPCI R6760S rear board and th...

Page 73: ...ble Disable Table 2 40 JP3 cPCI R6760S LAN4 Enable Disable LAN3 JP2 Disable Enable Default Table 2 39 JP2 cPCI R6760S LAN3 Enable Disable LAN4 JP3 Disable Enable Default 3 2 1 3 2 1 3 2 1 3 2 1 Artisa...

Page 74: ...S 232 Default unused 3 5 4 6 3 5 4 6 5 6 RS 422 3 5 4 6 1 3 2 4 1 3 2 4 3 4 RS 485 3 5 4 6 1 3 2 4 1 3 2 4 1 2 RS 485 1 3 2 4 1 3 2 4 1 3 2 4 1 2 Table 2 41 JP4 7 COM2 Mode Selection on cPCI R6760S re...

Page 75: ...mission or receiving by software Pin Signal Function 1 KBDATA Keyboard Data 2 NC No Connect 3 GND Ground 4 5V Power 5 KBCLK Keyboard Clock 6 NC No connect Table 2 42 Keyboard Connector on cPCI R6760S...

Page 76: ...85 1 DCD Data carrier detect TX DATA 2 RXD Receive data TX DATA 3 TXD Transmit data RX NC 4 DTR Data terminal ready RX NC 5 GND Ground GND GND 6 DSR Data set ready NC NC 7 RTS Request to send NC NC 8...

Page 77: ...6 CTS Clear to send NC NC 8 RI Ring indicator NC NC 10 NC No connection NC NC Table 2 46 Serial Ports COM2 pin headers CN13 on cPCI R6760S rear board Pin Signal Name 1 DCD Data carrier detect 3 RXD Re...

Page 78: ...17 Select PD3 parallel data 3 5 18 Ground PD4 parallel data 4 6 19 Ground PD5 parallel data 5 7 20 Ground PD6 parallel data 6 8 21 Ground PD7 parallel data 7 9 22 Ground ACK acknowledge 10 23 Ground B...

Page 79: ...g BLUE 6 HSYNC Horizontal sync 7 VSYNC Vertical sync 8 5V 5V 9 NC No Connect 10 GND Ground 11 GND Ground 12 GND Ground 13 GND Ground 14 GND Ground Table 2 49 VGA pin headers CN5 on cPCI R6760S rear bo...

Page 80: ...D0 17 18 DD15 Ground 19 20 keypin DMARQ 21 22 Ground DIOW 23 24 Ground DIOR 25 26 Ground IORDY 27 28 CSEL DMACK 29 30 Ground INTRQ 31 32 reserved DA1 33 34 PDIAG DA0 35 36 DA2 CS0 37 38 CS1 DASP 39 40...

Page 81: ...round 11 12 DS1 Ground 13 14 DS0 Ground 15 16 MTR1 Ground 17 18 FDIR Ground 19 20 STEP Ground 21 22 WDATA Ground 23 24 WGATE Ground 25 26 TRACK0 Ground 27 28 WPT Ground 29 30 RDATA Ground 31 32 HDSEL...

Page 82: ...0 GROUND DFFSENSE 31 32 LVEXT68 LVTRMPWR 33 34 LVTRMPWR LVTRMPWR 35 36 LVTRMPWR N C 37 38 N C GROUND 39 40 GROUND LVATNP 41 42 LVATNM GROUND 43 44 GROUND LVBSYP 45 46 LVBSYM LVACKP 47 48 LVACKM LVRSTP...

Page 83: ...12 GND DS0 DRVDEN1 MTR0 INDEX WDATA GND 11 GND DS1 DSKCHG MTR1 DRVDEN0 RDATA GND 10 GND WRTPRT HDSEL FDIR TRACK0 STEP GND 9 GND WGATE ERRORP AUTOFD PBUSY Reserved GND 8 GND PE SLCTIN 5V PSTROB Reserv...

Page 84: ...ND S2DEVSEL GND Reserved 1 SS2TOP S2LOCK GND 15 GND 3 3V S2FRAME S2IRDY GND S2TRDY GND 12 14 KEY 11 GND S2AD 18 S2AD 17 S2AD 16 GND S2C BE 2 GND 10 GND S2AD 21 GND 3 3V S2AD 20 S2AD 19 GND 9 GND S2C B...

Page 85: ...W SDIOR GND 12 GND SPDIAG SDCS16 SDDACK GND SDIRQ15 GND 11 GND SDA0 GND V I O 1 SDA2 SDA1 GND 10 GND GREEN SDACT SDCS3 GND SDCS1 GND 9 GND HSYNC GND V I O 1 RED BLUE GND 8 GND DDCCLK DDCDAT SPDLED2 GN...

Page 86: ...transfer rate ON 100Mbps transfer rate Table 2 57 Amber LED indication in LAN port Green LED Link Activity Status Description OFF No link ON Connecting Blinking Active Data transferring Table 2 58 Gr...

Page 87: ...74 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 88: ...III Celeron processors of 100MHz front side bus FSB frequency The CPU on cPCI 6760D series products is soldered onto the PCB printed circuit board in the factory The heatsink is also pre mounted in th...

Page 89: ...her reliability plus cost effective standard interface and has also been widely accepted in the industrial and mission critical embedded application field In cPCI 6760D the CF card socket can be found...

Page 90: ...all the CF card adaptor Please refer to the HDD installation section for instructions on removing the 2 5 ATA HDD DB 6760CF Outline Jumper and Connectors Figure 3 1 DB 6760CF Outline M S Selection JP1...

Page 91: ...Removing DB 6760CF from cPCI 6760D X Remove the upper screw which keeps the CF card in place X Remove the CF card by push ejector X Remove all screws and hexagonal pillars on the DB 6760CF X Remove DB...

Page 92: ...ce the user should remove the CF card adaptor if any first then install the 2 5 ATA HDD or FFD Please refer to CF installation for instructions on removing the CF card adaptor HDD FFD Installation for...

Page 93: ...6402 series backplane As the cBP 6108 series backplane has direct connections for J3 P3 and J5 P5 rear I O of IDE interfaces and pin assignments are compatible with the cPCI 6760D series product users...

Page 94: ...ter slave conflict Note that those backplanes should support P3 to P5 the CompactPCI sockets with direct through I O on system slot Note The 2 5 ATA HDD or CF card on front board utilizes the Secondar...

Page 95: ...the cPCI 6760D Model Variations Comparison Table in section 1 2 for the correct front board and rear board combinations The I O implementation is supported by both rear I O and front I O Several I Os...

Page 96: ...wiring by setting the mini switch There are four mini switches located on the bottom side solder side of cPCI 6760D Please refer to the following information when choosing either front I O or rear I O...

Page 97: ...Connecting Selection LAN 2 Connecting Switch S3 Switch S4 Pin State Pin State Front I O S3 1 ON S4 1 OFF S3 2 ON S4 2 OFF S3 3 ON S4 3 OFF S3 4 ON S4 4 OFF Rear I O S3 1 OFF S4 1 ON S3 2 OFF S4 2 ON...

Page 98: ...connection The 40 wire IDE cable can be connected to both backplane and rear board when the total cable length is not more 45cm Pay attention to the master slave settings to prevent settings conflict...

Page 99: ...86 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 100: ...Windows NT 1 Install the LAN driver before installing any service pack 2 Install the VGA AGP driver after installing the service pack Ensure the service pack supports AGP ADLINK recommends using servi...

Page 101: ...VGA controller SM721 The relative drivers are in the following ADLINK CD directory X CHIPDRV VGA SM721 where X is the location of the CD ROM drive The VGA drivers for Windows 98 95 Windows NT and Win...

Page 102: ...the Video Controller or Silicon Motion Lynx3DM entry 4 Click on the Driver tab then click Update Driver 5 On the Upgrade Device Driver Wizard window click NEXT 6 Select Display a list of and click NE...

Page 103: ...Double click on the Display Adapters entry and select Standard PCI Graphics Adapter VGA Click Properties 4 Click Driver then Update Driver 5 An Upgrade Device Driver Wizard windows will appear click N...

Page 104: ...which is located in the following path X CHIPDRV VGA SM721 WINNT40 highlight smisetup inf click OPEN then OK 5 A windows will display the Silicon Motion Lynx Family click OK then Yes to continue 6 An...

Page 105: ...he 82559 drivers support the following OS or platforms X Windows 98 Windows 95 Windows 2000 Windows NT X Novell Netware DOS Setup for Novell NetWare DOS X UNIX OS2 Linux All of the drivers above are i...

Page 106: ...e click Intel 8255x based PCI Ethernet Adapter 10 100 4 Select the Driver tab then click Update Driver 5 An Upgrade Device Driver Wizard windows will appear click Next 6 Select Display a list of and c...

Page 107: ...er 10 100 entry Click Properties 4 Click on the Driver button then click Update Driver 5 Update Device Driver Wizard starts click NEXT 6 Select Display a list of and click NEXT The next window allows...

Page 108: ...o the new drivers by following the instructions below 1 From Control Panel double click the Network icon a Network Configuration window will pop up click Yes 2 In Network Setup Wizard click Next click...

Page 109: ...Windows 98 Windows 95 Windows 2000 Windows NT 4 0 X Novell Netware DOS Setup for Novell NetWare DOS X UNIX OS2 Linux All of the above drivers are included in the ADLINK CD In this section the driver i...

Page 110: ...XXX PCI SCSI Adapter 4 Click on the Driver tab then click Update Driver 5 An Upgrade Device Driver Wizard window will start click NEXT 6 Select Display a list of the known drivers for this device so t...

Page 111: ...Logic xxxxx SCSI PCI Host Adapter Click the Properties button 4 Click Driver then click Update Driver button 5 An Upgrade Device Driver Wizard window will appear click NEXT 6 Select Display a list of...

Page 112: ...4 A screen should display the following message Setup has recognized the following mass storage devices in your computer 5 Choose S to configure additional SCSI adapters when a screen displays SCSI ad...

Page 113: ...etup inf click Open then OK The previous window appears with the selected driver displayed as the driver to install 5 In the Window NT Setup window type A WINNT MINIPORT driver in the dialog box then...

Page 114: ...O chip and two Watchdog control registers CRF4 and CRF3 of logical device 8 We provide the WDT function calls for easy use under DOS Windows 95 98 2000 and Windows NT please refer to the information...

Page 115: ...e WDT Under DOS Windows 95 or 98 Open a DOS command prompt and execute the following utility on the CD X CHIPDRV WDT test n n second value This program can auto detect which Super I O chip to use Unde...

Page 116: ...tware is stored on the ADLINK CD under X Utility HWDoctor W8378X WIN98 and X Utility HWDoctor W8378X NT40 Please install the Hardware Doctor by executing the HWM 98 exe or HWM NT exe respectively unde...

Page 117: ...adapter fails the secondary takes over Up to eight Fault Tolerance teams can be created Each team can have 2 8 ports or adapters 2 Adaptive Load Balancing ALB Creates a team of two to eight Ethernet...

Page 118: ...a peripheral board has changed The cPCI 6760D then performs any necessary maintenance such as installing a device driver upon board insertion or quiescing a device driver and the board prior to the bo...

Page 119: ...heral board is in an unstable state while pins are first mated This duration can potentially be infinite if the board is just marginally connecting the longest pins 8 Enough pins are connected that a...

Page 120: ...to chassis ground through a bleed resistor 8 The board is extract from the ESD card guide 9 The board is uninstalled If it is not necessary to support Hot Swap Capability users could disable the func...

Page 121: ...tting for Self Hot Swap BIOS Setting Process 1 Power ON the computer 2 Press the Delete Key 3 Under BIOS Menu choose Power Management Setup 4 Choose ACPI Function set this item to Enable 5 Press F10 S...

Page 122: ...Advanced Sheet 4 Choose When I press the power button on my computer set it to Power OFF 5 Click OK then exit Note If operators wish to use the handle as the power button and shut down OS automaticall...

Page 123: ...ed that a stable Early Power can be achieved And the BLUE LED is in the ON state 5 The board contacts the medium length pins on the backplane Medium length power pins contact and short out the current...

Page 124: ...f the blue LED is on this would indicated one of two things the OS was shut down properly by triggering the button with handle still closed or the operator forced the OS to shut down with the handle s...

Page 125: ...in When operators want to hot insert or extract the board check that all of the backplane s power come from P1 This will ensure all power is isolated and controlled when the card is inserted and extra...

Page 126: ...ll be covered by the original manufactur ers warranty X For products containing storage devices hard drives flash cards etc please back up your data before send ing them for repair ADLINK is not respo...

Page 127: ...teries by customer user X Damage from improper repair by unauthorized ADLINK technicians X Products with altered and or damaged serial numbers are not entitled to our service X This warranty is not tr...

Page 128: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: