78
Getting Started
DB-6760CF Installation for cPCI-6760D and CF card notice
X
Mount the DB-6760CF on cPCI-6760D’s IDE connector
(CN2). Note that pin 1 on DB-6760CF should be aligned
with pin 1 of cPCI-6760D’s CN2.
X
Fix the DB-6760CF and cPCI-6760D by screwing three
hexagonal pillars between them. Leave the hole in front of
the CF socket unscrewed.
X
Set the CF card as master or slave upon application
request.
X
Insert the CF card into the socket ensuring the CF card is in
place.
X
Mount the third screw on the upper side of the CF card to
prevent the CF card from dropping out during heavy
vibrations.
Removing DB-6760CF from cPCI-6760D
X
Remove the upper screw which keeps the CF card in place
X
Remove the CF card by push ejector
X
Remove all screws and hexagonal pillars on the DB-
6760CF
X
Remove DB-6760CF carefully from the 44-pin IDE
connector (CN2) of cPCI-6760D
Note:
The CF card on the front board utilizes Secondary
EIDE interface (IDE2) which is also wired to the rear
board via CompactPCI connector J5. Users need to be
aware of the master/slave setting to avoid conflict
between devices. The default jumper setting on DB-
6760CF is set to “master”. As each EIDE interface can
only support up to two IDE devices, the IDE2 interface
on rear I/O can only support one other IDE device.
This should be set to “slave”.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for NuIPC cPCI-6760D Series
Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 87: ...74 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 99: ...86 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...