138
Spheras Storage Director Installation and User Guide
39
Name
MLXEV_PHYSDEV_SCSITMO_DEAD
Description A physical disk failed because a command to the disk timed out.
Cause
SCSI command timed out on the device.
Action
Replace physical disk and rebuild it.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
40
Name
MLXEV_PHYSDEV_SYSRESET_DEAD
Description A physical disk failed because of the system reset.
Cause
System reset occurred.
Action
Replace physical disk and rebuild it.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
41
Name
MLXEV_PHYSDEV_BSYPAR_DEAD
Description A physical disk failed because of busy status or parity error.
Cause
The physical disk returned busy status.
The SCSI transaction with the physical disk met with parity error.
Action
Replace physical disk and rebuild it.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
42
Name
MLXEV_PHYSDEV_BYCMD_DEAD
Description A physical disk set to failed state by host.
Cause
Command from host set the physical disk to failed state.
Action
Replace physical disk and rebuild it.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
43
Name
MLXEV_PHYSDEV_SELTMO_DEAD
Description A physical disk failed because access to the device met with a selection
time out.
Cause
Physical disk disconnected or powered off.
Physical disk failure.
Action
Replace physical disk and rebuild it.
Check power and cabling.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
44
Name
MLXEV_PHYSDEV_SEQERR_DEAD
Description A physical disk failed because of a sequence error in the SCSI bus
phase handling.
Cause
Physical disk failure.
Action
Replace physical disk and rebuild it.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
45
Name
MLXEV_PHYSDEV_UNKNOWNSTS_DEAD
Description A physical disk failed because device returned an unknown status.
Cause
Bad physical disk or incompatible device.
Action
Replace physical disk or the device and rebuild it.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
Table 2
RAID Controller Event Codes
Summary of Contents for MAN-00005-UG
Page 11: ...12 Spheras Storage Director Installation and User Guide ...
Page 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Page 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Page 53: ...54 Spheras Storage Director Installation and User Guide ...
Page 65: ...66 Spheras Storage Director Installation and User Guide ...
Page 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Page 199: ...200 Spheras Storage Director Installation and User Guide ...