© 2003, Adaptec, Inc.
131
Usually a non-optimal logical drive or physical device failure.
User action is needed to prevent data loss or loss of access to data.
User may need to replace hardware.
Resources in a serious state should be considered Vulnerable according to RAB guidelines.
6.9.4.3
Warning
Icon:
An error has occurred that did not cause data loss, usually a software error. User may need to retry a command.
6.9.4.4
Informational or Optimal
Icon:
A warning or condition that does not require immediate user action, but may become more serious.
Resources in the warning state should be considered Vulnerable according to RAB guidelines.
6.9.4.5
Events Icon:
Everything is good, no action is required.
Resources in an informational/optimal state should be considered Protected according to RAB guidelines.
6.9.5
RAID Controller Event Codes
Event
1
Name
MLXEV_PHYSDEV_ONLINE
Description A physical disk has been placed online.
Cause
Rebuild completed.
Physical disk was configured.
Manual online was done.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
ExPro InPro
2
Name
MLXEV_PHYSDEV_HOTSPARE
Description A physical disk was added as a hot spare.
Cause
Device was configured.
Manual hot spare was done.
Automatic hot spare was done.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
InPro
Table 2
RAID Controller Event Codes
Summary of Contents for MAN-00005-UG
Page 11: ...12 Spheras Storage Director Installation and User Guide ...
Page 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Page 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Page 53: ...54 Spheras Storage Director Installation and User Guide ...
Page 65: ...66 Spheras Storage Director Installation and User Guide ...
Page 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Page 199: ...200 Spheras Storage Director Installation and User Guide ...