© 2003, Adaptec, Inc.
147
91
Name
MLXEV_PPILOT_PRIMARY_DISK_NOT_FOUND
Description A primary logical drive was not found during initialization.
Cause
PATHPilot reported a primary logical drive was lost during power
cycle.
Action
Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address
PATHpilot: Last HBTL: 12,13,14,15
Severity
3 (Warning)
Source
PATHpilot
92
Name
MLXEV_PPILOT_NO_PATH_FOR_LD_FOUND
Description No paths were found for a logical drive during initialization.
Cause
PathPilot reported all paths were lost to a logical drive during power
cycle.
Action
Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address
PATHpilot: Last HBTL: 12,13,14,15
Severity
3 (Warning)
Source
PATHpilot
93
Name
MLXEV_PPILOT_RECOVERY_ON_STANDBY_PATH
Description A standby path has been recovered.
Cause
PathPilot reported recovery of a standby path.
Action
None. This indicates that storage access has been restored.
Address
PATHpilot: Curr HBTL: 12,13,14,15
Severity
4 (Information)
Source
PATHpilot
94
Name
MLXEV_PPILOT_PATH_FAILURE_ON_STANDBY_PATH
Description A standby path failed.
Cause
PathPilot reported a failure on a standby path.
Action
Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address
PATHpilot: Curr HBTL: 12,13,14,15
Severity
3 (Warning)
Source
PATHpilot
95
Name
MLXEV_REPLACED_PHYSDEV_SMALLER
Description User replaced a configured physical disk with a disk of smaller
capacity.
Cause
The new physical disk may have a smaller physical capacity than the
physical disk it replaced.
The controller's coercion setting may have reduced the configurable
size of the new physical disk.
Action
None.
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
InPro
96
Name
MLXEV_FIBREDEV_LOOPID_SOFTADDR_OCCURRED
Description Device loop ID conflict (soft addressing) detected.
Cause
Device loop ID conflict detected on a disk channel resulted in soft
addressing; potential data corruption.
Action
Change index selector to enable hard addressing per enclosure
manufacturer’s specification.
Address
ctl: 0 chn: 13
Severity
1 (Serious)
Source
ExPro
Table 2
RAID Controller Event Codes
Summary of Contents for MAN-00005-UG
Page 11: ...12 Spheras Storage Director Installation and User Guide ...
Page 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Page 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Page 53: ...54 Spheras Storage Director Installation and User Guide ...
Page 65: ...66 Spheras Storage Director Installation and User Guide ...
Page 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Page 199: ...200 Spheras Storage Director Installation and User Guide ...