© 2003, Adaptec, Inc.
161
332
Name
MLXEV_ENCLACCESS_OFFLINE
Description Enclosure access is offline.
Cause
Enclosure management connection is broken.
Management hardware failure.
Action
Refer to enclosure manufacturer’s service manual.
Address
ctl: 0 enclosure: 13
Severity
1 (Serious)
Source
ExPro InPro
333
Name
MLXEV_ENCLSES_SOFTADDR_OCCURRED
Description Enclosure soft addressing detected.
Cause
Enclosure has duplicate loop IDs (soft addressing). Potential data
corruption.
Action
Refer to enclosure manufacturer’s service manual.
Address
ctl: 0 enclosure: 13
Severity
1 (Serious)
Source
ExPro
334
Name
MLXEV_ENCLACCESS_READY
Description Enclosure services ready.
Cause
–
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
335
Name
MLXEV_ENCLHEAT_UNKNOWN
Description Access to temperature sensor has been lost.
Cause
Module containing temperature sensor has been removed.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro
336
Name
MLXEV_ENCLPOWER_UNKNOWN
Description Access to power supply status information has been lost.
Cause
Module establishing connectivity has been removed.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro
337
Name
MLXEV_ENCLFAN_UNKNOWN
Description Access to fan status information has been lost.
Cause
Module establishing connectivity has been removed.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro
Table 2
RAID Controller Event Codes
Summary of Contents for MAN-00005-UG
Page 11: ...12 Spheras Storage Director Installation and User Guide ...
Page 28: ... 2003 Adaptec Inc 29 Figure 12 Installation Welcome ...
Page 34: ... 2003 Adaptec Inc 35 Figure 19 Client installation complete ...
Page 53: ...54 Spheras Storage Director Installation and User Guide ...
Page 65: ...66 Spheras Storage Director Installation and User Guide ...
Page 192: ... 2003 Adaptec Inc 193 Figure 105 Open Image File Dialog Box ...
Page 199: ...200 Spheras Storage Director Installation and User Guide ...