Functional Description
© 2018 ACTIA I+ME GmbH │ Ref. IR:14938
28
/
92
9.2
Functions
9.2.1
Key Switch Positions
Pos.
Symbol
Operating sta-
tus
Remark
a
OFF
BOP xD is or will be
switched off.
After the automatic
shutdown of the elec-
tromagnetic locking the
slide disk may be re-
moved.
b
RECORDING
BOP xD
is recording vid-
eo data as per the con-
figuration settings.
Table 3) Key Switch Positions
The Ethernet interface on the back is used for:
System configuration web interface
Password-secured data transfer SMB/CIFS
Firmware update
The Ethernet interface on the front is used for
Service interface
Maintenance
9.2.2
Configuration
The system is configured over an easy-to-use web interface, see Chapter 11, Web
Interface. To this end, a free web browser (e.g. Internet Explorer as of v. 8.0, Firefox
or similar products) is required.
9.2.3
Secondary Functions
The recorded data can be output on parallels connected monitors. In the event of an
alarm, the alarm data is transferred automatically via an external modem (e.g.
xNet).