Web Interface
© 2018 ACTIA I+ME GmbH │ Ref. IR:14938
55
/
92
12.5.1.13
Error Signalling Time
The error signalling time indicated how long an error will be signalled by the service
LED and relay 4. The effect of the error signalling time depends on the setting >One-
time error signalling<.
0 Error is signalled until the err.txt file is deleted
0 .. 1440 Error is signalled for the defined time
(Indicated in minutes, whereby 1440 = 24 hours)
12.5.1.14
One-time Error Signalling
>One-time error signalling< replaces >Error signalling time<.
0 = Setting disabled, error signalling time is now enabled
1 = An error is signalled as a 2-seconds long one-off impulse via the
service LED and relay 4 and it is entered into the error file err.txt.
2 = Relay 4 and the service LED remain on as of the first error entry
and until the error has been eliminated.
One-time error signalling - 0 = OFF, 1 = One-off impulse, 2 = error
There is an additional error relay output. Value 1-4 defines an additional error relay
output. The default “All OK status” is disabled, the relays is enabled when no further
recording is possible. When no video signal is delivered, the relays blink.
12.5.1.15
Error Messages
You can configure the messages (error messages) at the video output as well as the
stop at the video output. Error messages are displayed when a camera or a
passenger counting device is out of commission. The error message or the stops are
displayed on the monitors.
You can configure an automatic restart.
12.5.1.16
Inputs
Pause input #4 - 0 = OFF, 1 = digital input, #4 stops the recording
(customer specific)