Web Interface
© 2018 ACTIA I+ME GmbH │ Ref. IR:14938
53
/
92
Switch-off delay - between 0 and 120 min after the ignition has been
switched off
12.5.1.8
Pre-Alarm and Post-Alarm Buffer
When there is a pending alarm, all recorded data is additionally saved in
a separate folder for a set time (/hdd/alarm/). The alarm storage limit
displays the percentage of the data storage total capacity that is
available for the recording of alarm data. When the limit is exceeded, a
message is entered into the err.txt error file thus activating the
maintenance message on the homepage. The alarm data is recorded even
after the storage limit is exceeded thus reducing the buffer storage.
Pre-alarm time - between 5 and 180 min recording period before the
alarm signal
Post alarm time - between 5 and 180 min recording period after the
alarm signal
12.5.1.9
Maximum Storage Time
The maximum storage time shows how long the data is saved in the
buffer storage. All data that is ol der than the set period is automatically
deleted. The
BOP
system time is of relevance for time comparisons.
Max. storage time – 0-23:59 min, value [abs]
If the value [abs] = 0, all older sequences are deleted. If the value [abs] = 1, all
sequences for which the sequence time multiplied by the number of sequences is
more/higher than the defined storage time are deleted.
12.5.1.10
Alarm Data
Alarm limit - 1 to 1000 max. number of alarms triggered in the alarm
storage, if the value is e.g. 3, all older alarms in the ala rm storage
are pushed back.
Alarm Data Age - 14.90 to 365 days - older alarm data is pushed back
in the alarm storage.
Flank alarm input - defines the trigger direction - 0 = up, 1 = down