The age of the recorded data is calculated by:
Activating the function,
Creation time of the current
BOP
system time.
10.3
Alarm
For the alarm, there must be a “high active” signal on the 21-pin “I/O” plugs “Pin 9”
or “Pin 2”.
The lead and follow-up time can be set under [General Settings] on the
[Configuration] site. The alarm data is stored in a secure storage area and is kept
until manually deleted.
10.4
Recording Additional Data
Beside the video data with the time stamp, the following additional data can also be
found:
Camera name (set under Configuration)
Vehicle number
Route
Stop
Vehicle identification
BOP
saves the log files that protocol the behaviour of the recorder. All IBIS functions
are checked during a test run and adjust via “ON” if necessary.
10.5
IBIS Time Correction
Date and Time are corrected by the real-time clock (RTC) via IBIS or GPS if there is a
deviation of more than 30 seconds. By deviation of more than 2 minutes, the system
is restarted. The IBIS time correction can be set under Configuration. The time can
be automatically applied to a preconfigured time which requires a restart.