Network Functionality
© 2018 ACTIA I+ME GmbH │ Ref. IR:14938
38
/
92
11.4
Data Access from the Headquarters
The headquarters can access the CCTV system data if there is a LAN connection. If
the router has access to the Internet, the LAN connection must be established
through a secured tunnel. Such access is possible after it is enabled. Enabling and
Blocking is possible only via the [Live account]. The account has the following access
rights:
WEB server (live images, maintenance),
SMB/CIFS/Samba (recorded data),
FTP server (recorded data),
The assault button/ emergency call is connected to ALARM input “IN 6” (21pinsPin9)
of the CCTV system. Triggering the alarm informs the headquarters (UDP datagram
broadcast - Port 30603: 0, "ALARM").
Triggering the alarm enables access to data from the headquarters without a time
limit. A data access acknowledgment from the headquarters starts a 60 minutes
timer. After the 60 minutes time expires, the data access is disabled. A repeated
alarm trigger stops the running 60 minutes timer. The data access acknowledgment
is executed via the Web server in the [Maintenance] menu. The data access
acknowledgement can be withdrawn.
Time limit cancellation
Timer stop
A new acknowledgment resets the timer to 60 minutes.
11.5
Data Transfer Options
11.5.1
Current Camera Images
The web server menu “Live images” provides the possibility to control the camera
images and signals of Videooutput#1 (monitor output). The Videooutput#1 stream
can be controlled via an additional browser window [VOut#1 control]. This makes it
suitable for camera control via LAN connections, such as over a secured VPN tunnel
of a router via UMTS/LTE to a server.