Chapter 4 - SCSISelect Configuration Utility 4-11
Arrow keys to move cursor, <Enter> to select option, <Esc> to exit ( =default)
Adaptec AIC7880 Ultra/Ultra W SCSISelect (TM) Utility
AIC-7880 Ultra/Ultra W at Bus:Device 01:06h
Configuration
SCSI Bus Interface Definitions
Host Adapter SCSI ID ................................ 7
SCSI Parity Checking................................. Enabled
Host Adapter SCSI Termination ................. Low ON/High ON
Additional Options
Boot Device Options .................................. Press <Enter>
SCSI Device Configuration......................... Press <Enter>
Advanced Configuration Options ................ Press <Enter>
<F6> - Reset to Host Adapter Defaults
SCSI Device Configuration
SCSI Device ID #0 #1 #2 #3 #4 #5 #6 #7
Initiate Sync Negotiation ............. yes
yes
yes
yes
yes
yes
yes
yes
Maximum Sync Transfer Rate .....40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
Enable Disconnection ................. yes
yes
yes
yes
yes
yes
yes
yes
Initiate Wide Negotiation ............. yes
yes
yes
yes
yes
yes
yes
yes
--------------------Options Listed Below Have NO EFFECT if the BIOS is Disabled -----------------
Send Start Unit Command ........... no
no
no
no
no
no
no
no
Include in BIOS Scan .................. yes
yes
yes
yes
yes
yes
yes
yes
SCSI Device ID #8 #9 #10 #11 #12 #13 #14 #15
Initiate Sync Negotiation ............. yes
yes
yes
yes
yes
yes
yes
yes
Maximum Sync Transfer Rate .....40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
Enable Disconnection ................. yes
yes
yes
yes
yes
yes
yes
yes
Initiate Wide Negotiation ............. yes
yes
yes
yes
yes
yes
yes
yes
--------------------Options Listed Below Have NO EFFECT if the BIOS is Disabled -----------------
Send Start Unit Command ........... no
no
no
no
no
no
no
no
Include in BIOS Scan
yes
yes
yes
yes
yes
yes
yes
yes
SCSI Device Configuration
Figure 4-7 SCSI Device Configuration Screen for AIC-7880
Use the cursor keys (
↑
↓
) to move between options. Press Enter to display a pop-
up menu with a selection of values. Use the cursor keys (
↑
↓
) to select a value, and
press Enter to make your selection.
Initiate Sync Negotiation
This option determines whether the SCSI controller initiates synchronous
negotiation with the SCSI device.
When set to yes, the SCSI controller initiates synchronous negotiation with the
SCSI device. When set to no, the SCSI controller does not initiate synchronous
negotiation. The SCSI controller, however, always responds to synchronous
negotiation if the SCSI device initiates it. The default setting is yes.
Summary of Contents for Altos 9100 Series
Page 1: ...AcerAltos 9100 Series User s Guide ...
Page 115: ...Chapter 5 System Housing 5 15 5 Connect the signal and power cables to the drive ...
Page 125: ...Chapter 5 System Housing 5 25 5 9 2 Connecting a Keyboard ...
Page 126: ...AcerAltos 9100 Series User s Guide 5 26 5 9 3 Connecting a Mouse Mouse ...
Page 127: ...Chapter 5 System Housing 5 27 5 9 4 Connecting a Printer ...
Page 128: ...AcerAltos 9100 Series User s Guide 5 28 5 10 Complete System Connections ...