Chapter
6 Monitoring and Diagnostics
Installation and Operation Manual
6-8
Monitoring Performance
ACE-3105, ACE-3205 Ver. 5.2
Parameter Description
Possible
Values
Valid intervals
Number of saved intervals
0–24
Interval
The interval number to be displayed
0–last interval, max 24
0 if no interval
Default: 0
Recovered ID
ID of the clock stream for which the details
above are displayed
1
PW number
Number of the pseudowire connection that
is associated with the recovered clock ID.
Read-only.
1
Viewing the Current Clock Source Details
You can display the details of the clock source (master or fallback) from which
ACE-3105, ACE-3205 currently recovers its timing reference. The master and
fallback clock sources must be pre-configured prior to monitoring them (for more
information, see
in Chapter 4).
³
To view the details of the current clock source:
•
From the Clock monitoring menu, select Current Clock.
The details of the current clock source are displayed (read-only).
ACE-3205 – RAD Data Communications
Monitoring> System> Clock> Current clock
Active clock ... (Master)
Source ... (RX clock)
Port type ... (0)
Port number ... (0)
Recovered ID ... (1)
Clock State ... (Hold over)
Qualified clock ... (Qualified)
>
ESC-previous menu; !-main menu; &-exit
Figure
6-10. Current Clock Source Details