Installation and Operation Manual
Chapter
4 Configuration
ACE-3105, ACE-3205 Ver. 5.2
Configuring for Operation 4-51
ACE-3205 – RAD Data Communications
Configuration> System> Clock> Recovered clock
1. ID > (1)
2. Activity > (Enable)
3. Type > (Adaptive)
4. PW number ... (1)
5. Source quality > (Stratum1)
6. Network type > (Type B)
>
Please select item <1 to 6)
ESC-previous menu; !-main menu; &-exit
Figure
4-40. Recovered Clock Menu
Table
4-34. rameters
Parameter Description
Possible
Values
ID
Defines the clock recovery entity
1
Activity
Enables or disables the clock recovery
functionality. Once enabled, the clock
recovery is immediately activated,
Enable
Disable
Default: Disable
Type
Type/method of the clock recovery.
Note: The type cannot be changed if the
clock recovery is enabled.
Adaptive
PW number
Number of the specific pseudowire
connection on which the clock stream is
carried. The PW type must me preset as
'clock recovery'. For more information
about PW connection creation, see
Creating Pseudowire (PW) Connections.
ACE-3105, ACE-3205 uses up to 32 PWs
for data, up to 32 PWs for clock
distribution, and up to 2 PWs for clock
recovery.
1–66
Source quality
Defines the required accuracy level of the
recovered clock source.
Note:
•
Stratum 3 and Stratum 4 are available
only when the selected network type
is Type B (see below).
•
The source quality selection cannot
be changed when Activity is set to
Enable.
Stratum 1
Stratum 2
Stratum 3
Stratum 3E
Stratum 4
Default: Stratum 1