Remote Station - Guide Point Adjust
91
Parameters
This section provides a basic procedure for setting the Remote Station parameters and also
describes each parameter in detail.
The Operation section of this manual (page 90) describes the operation of the Remote Station
front panel keys and display.
Job Profile
J o b P r o f i l e 1
The Remote Station can store up to 25 unique parameter
configurations (called
job profiles
) that make material
changeover faster and less error-prone. When a job profile
is selected, all previously stored parameter settings for that
job are instantly recalled.
To save a new job profile, select an unused profile
number, then change the other parameters as needed.
To modify an existing job profile, select its profile number,
then change the other parameters as needed.
To recall a job profile, select the profile number.
Note
: When AC power is turned on the system will
automatically reload the job profile that was selected and
in use when AC power was lost.
The default value is 1.
Range: 1 to 25
Offset 1
O f f s e t 1 0 . 0 0 0
Offset 1 is typically used for setting the guide point position
- when in Automatic mode the guide will maintain the web
at this position. The offset is displayed in
inches
or
millimeters
.
The default value is 0.000.
Range:
±
16.300” [
±
414.0 mm]
Offset 2 – Not available on the EVO 150
O f f s e t 2 0 . 0 0 0
Offset 2 is typically used for setting a
second
guide point
position in applications that require PLC control of guide
point position. The controller’s AUXILIARY input
determines which offset is active – Offset 1 or Offset 2.
Refer to page 47 for more information about the
AUXILIARY input. The offset is displayed in
inches
or
millimeters
.
The default value is 0.000.
Range:
±
16.300” [
±
414.0 mm]
Summary of Contents for EVO 150
Page 1: ...P O Box 7816 Madison Wisconsin 53707 7816 Instruction Manual EVO 150 Web Guide Control System...
Page 2: ......
Page 6: ...EVO 150 Controller 4 EVO 150TM Web Guide Control System...
Page 56: ...PointSource and WideArray Edge Detectors 54 PointSource and WideArray Edge Detectors...
Page 62: ...AccuBeam 3 Digital Line Guide Sensor 60 AccuBeam 3 Digital Line Guide Sensor...
Page 85: ...AccuWeb Linear Actuators 83 AccuWeb Linear Actuators...
Page 90: ...Remote Station Guide Point Adjust 88 Remote Station Guide Point Adjust...
Page 99: ...Remote Station Auxiliary 97 Remote Station Auxiliary...
Page 104: ...Fieldbus Interface 102 Fieldbus Interface...
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ...NOTES...