EVO 150 Controller
11
Operation
The EVO 150 may be configured for a wide variety of applications, but most configurations share
the same basic operating procedure:
1) Press the SERVO-CENTER button and wait for the web guide to drive to the center of travel.
2) Thread the web through the machine.
3) Position the sensors.
One edge detector:
Place the detector near the edge of the web. Move the detector towards
the web until its null indicator LED turns off.
Note:
The scribed lines on the edge detector
indicate the approximate location of the detector’s guide point.
Two edge detectors (centerline guiding):
Press the EDGE A button. Place detector A near
the edge of the web. Move detector A towards the web until its null indicator LED turns off.
Press the EDGE B button. Place detector B near the opposite edge of the web. Move
detector B towards the web until its null indicator LED turns off.
Note:
The scribed lines on
the edge detector indicate the approximate location of the detector’s guide point.
Digital line guide:
Position the sensor so that it is approximately centered over the
registration line or edge. When it is positioned correctly an indicator dot will appear in the
display under the line or edge you want to track. Refer to page 60 for more information about
operating the line guide.
4) Press the EDGE A, EDGE B, or LINE button. For Centerline mode (centerline guiding), press
the EDGE A and EDGE B buttons simultaneously.
5) Press the AUTOMATIC button. The system will now guide the web.
Scribe mark
Null indicator
Move detector until
null
indicator
turns
off
Web
Web
PointSource
detector
WideArray
detector
Centerline guiding with WideArray detectors
Guide Point Offset
Min Value
Guide Point Offset
Max Value
Summary of Contents for EVO 150
Page 1: ...P O Box 7816 Madison Wisconsin 53707 7816 Instruction Manual EVO 150 Web Guide Control System...
Page 2: ......
Page 6: ...EVO 150 Controller 4 EVO 150TM Web Guide Control System...
Page 56: ...PointSource and WideArray Edge Detectors 54 PointSource and WideArray Edge Detectors...
Page 62: ...AccuBeam 3 Digital Line Guide Sensor 60 AccuBeam 3 Digital Line Guide Sensor...
Page 85: ...AccuWeb Linear Actuators 83 AccuWeb Linear Actuators...
Page 90: ...Remote Station Guide Point Adjust 88 Remote Station Guide Point Adjust...
Page 99: ...Remote Station Auxiliary 97 Remote Station Auxiliary...
Page 104: ...Fieldbus Interface 102 Fieldbus Interface...
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ...NOTES...