![background image](http://html.mh-extra.com/html/abb/srea-01/srea-01_user-manual_219079.webp)
Configuration pages
79
The device list shows the names of the drives and their templates and Modbus
addresses. If the drives are connected to SREA-01, powered on and configured
properly, the easiest way to add new drives to the configuration list is to use the
autodetect function. The other option is to add each drive manually by using the ‘add
device’ button.
When the ‘autodetect’ button is pressed, the following popup window appears:
Make sure that the Modbus settings (port, baud rate and parity) correspond to your
setup. After that, press ‘start’ to start scanning for new drives. During the scanning
procedure, you can see how many new drives have been found. After all drives have
been found, you can stop scanning by pressing ‘cancel’. The found drives are added
to the list. By default, the drives are named by the template file and their Modbus
address.