5 Installation and Commissioning
5.6 Encoder and Sync Switch Installation
96
Product Manual, Control Cabinet IRC5P
CAUTION!
Placing the switch in the hazardous area means that the switch and its
connection MUST comply with the ex-regulations. Observe that the hazardous area
also includes areas just outside any spray booth opening as shown in
.
Figure 45 Ex sync switch connection
An ex type initiator may be used as alternative to a switch. Such a switch device in
conjunction with a transformer isolated barrier can be installed as shown in
Alternative B.
Initiator
Transformer
isolated barrier
Control cabinet
Non-hazardous area
Hazardous area
SCB-X7
2
3
4
1
ENC_3A-
GND
+24 VDC