5 Installation and Commissioning
Product Manual, Control Cabinet IRC5P
109
5.7 Misc. System Connections
5.7.7 Servo Disconnect
General
Servo disconnect remote on terminal is an option to remotely switch off the power
to the robot motors, while all other functions of the controller are still powered. The
principle diagram is shown in following illustration.
Figure 55 Servo disconnect remote on terminal, principle diagram
The terminal XT5 is located at the bottom of the controller, see
Max. cable length from control cabinet to external switch is 25 meter.
KM1
KM2
Optional servo disconnect
3 x 260/475VAC
Transformer
Servo Drive
Unit axes 1-6
system 1
XT5
1
4
2 3
5
6
MIB- X11
8
7
2
1