5 Installation and Commissioning
5.2 Component Installation
50
Product Manual, Control Cabinet IRC5P
Installation
The purge unit consists of the purge valve assembly and a purge connection. The
purge valve assembly can be mounted on the cabin wall or at another suitable
location, and the purge connector(s) can be placed at a convenient location, either in
the cable conduit or fastened to the cabin wall etc. using a suitable clamp. For
dimensions, see
Figure 21 Purge unit location and connections
Purge Air Hose
Connection
The hose between the purge valve unit and purge connection must be maximum
10 meters, but can be cut to required length. If the hose needs cutting, make sure
that the end with the orifice inside the hose is not cut off. This is also marked on the
hose. The hose must not be joined in a manner which will restrict the air supply.
Spray booth
Hazardous area
Supply air
Purge unit
Control
cabinet
Flexible hose
Motor and
control signals
Purge valve
control signal
Purge valve assy'
Purge air
hose
Supply air
Flexible hose to manipulator
Motor and signal cables
Single purge connection
Purge valve unit
Purge air hose
Hose can be cut at this end
Flow reducing
orifice
Purge connection
Ground clamp
Summary of Contents for IRC5P
Page 1: ...The heart of Robotics Product Manual Control Cabinet IRC5P 3HNA009834 001 en Rev 06 ...
Page 2: ......
Page 10: ...10 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Page 14: ...2 Safety 14 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P ...
Page 218: ...218 3HNA009834 001 en Rev 06 Product Manual Control Cabinet IRC5P Manual Status ...