8 Trouble Shooting
Product Manual, Control Cabinet IRC5P
187
8.3 Fault Symptoms and Malfunctions
8.3.13 Consistent Path Inaccuracy
Description
The path of the robot TCP is consistently inaccurate.
Consequences
Production is not possible.
Possible Causes
•
Robot not calibrated correctly.
•
Robot TCP not correctly defined.
•
Robot Base Frame, Object Frame or similar not correctly defined.
•
Wrong robot type may be connected to the controller.
Recommended Actions
Step Action
Comment
1
Make sure the robot Tool is correctly defined.
How to define the TCP is described in
the ‘Operator's Manual, IRC5P’.
2
Check the revolution counter.
If required, update revolution counter as
described in ‘Operator's Manual,
IRC5P’.
3
If required, re-calibrate the robot axes.
Make sure the robot is calibrated as
described in ‘Operator's Manual,
IRC5P’.
4
Check that all Frames are correctly defined.
How to configure frames is described in
‘Operator's Manual, IRC5P’.
4
Make sure the correct robot type is connected
as specified in the configuration files.